9
SUZ-KA18NA
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainar)
Stop valve
(with service port)
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(ø
3.6×ø2.4×50)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø1/2
(with heat insulator)
Refrigerant pipe ø1/4
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
Service port
Service port
Max. Length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model
Refrigerant piping: ft.
Piping size O.D: in.
Max. Length
A
Max. Height difference
B
Gas
Liquid
SUZ-KA09/12/15NA
65 40
3/8
(KA09/12)
1/2
(KA15)
1/4
SUZ-KA18NA
100 50
1/2
Unit: inch (mm)