background image

Be

tw

ee

n ri

bs

Before installing the grille, connect the junction wires included with the grille acces-
sories and place them in the connector box.

 Remove the two screws securing the wire cover of the main unit, and then open 

the cover.

 Route the wires of the i-See sensor and signal receiver through the wire inlets in 

the electric component box as shown in the diagram and around the bushings on 

secure the grille junction wire and the wires of the i-See sensor and signal receiver 
with the clamp.

 Remove the one screw securing the connector box cover, and then open the cover. 

 Place the junction wire connector in the connector box.
 Install the wire cover and connector box cover.

  Connector box cover
  Connector box

  Band

Содержание Mr.Slim SLZ-M15

Страница 1: ...STALLATION INSTALLATIEHANDLEIDING MANUAL DE INSTALACIÓN MANUALE DI INSTALLAZIONE MANUAL DE INSTALAÇÃO English Deutsch Français Nederlands Español Italiano Svenska Dansk Türkçe Norsk FOR MONTØR DLA INSTALATORA INSTALLATIONSMANUAL FÖR INSTALLATÖREN VOOR DE INSTALLATEUR FÜR INSTALLATEURE FOR INSTALLER TIL INSTALLATØREN ...

Страница 2: ...aintenance of the unit to the customer according to the information in the Operation Manual and perform the test run to ensure normal operation Both the Installation Manual and Operation Manual must be given to the user for keeping These manuals must be passed on to subsequent users This mark is for R32 refrigerant only Refrigerant type is written on nameplate of outdoor unit Read the OPERATION MA...

Страница 3: ...2 2 controller are surely received by the indoor unit from that position beep or beep or wall and set the wireless remote controller wireless remote controller may not be received 1 Safety precautions ...

Страница 4: ...Ceiling opening Outer side of Grille Grille Ceiling If setting the maintenance space for be sure to leave is a minimum of 700 mm Maintenance space Fresh air intake Angle Electric component box Leave the maintenance space at the electric component box end ensure a minimum space of 25 mm The indoor unit should be supplied with the following accessories Accessory name Q ty Installation template 1 4 4...

Страница 5: ...r wooden hang ers etc to install the suspension bolts Unit Grille Pillow Ceiling Rafter Beam Roof beam Use inserts rated at 100 150 kg Steel reinforcing rod Ceiling Suspend the main unit as shown in the diagram 1 In advance set the parts onto the suspension bolts in the order of the washers 2 Lift the unit to the proper height of the suspension bolts to insert the mounting plate between washers an...

Страница 6: ...ial mm inch SLZ M15 SLZ M25 SLZ M35 For liquid 6 35 0 8 mm 8 mm Heat resist ing foam plastic 0 045 gravity For gas 9 52 0 8 mm 8 mm SLZ M50 For liquid 6 35 0 8 mm 8 mm For gas 12 7 0 8 mm 8 mm SLZ M60 For liquid 6 35 0 8 mm 8 mm For gas 15 88 1 0 mm 8 mm order to avoid burrs drop in the tubing having completed burr removal Pipe diameter Dimension B 0 0 4 Clutch type 6 35 0 0 5 9 1 9 52 0 0 5 13 2 ...

Страница 7: ...Secure both ends of each pipe cover with the enclosed bands Attach the bands Make sure that the slit in the pipe cover is facing upward when it is installed all piping connections between indoor and outdoor unit have been completed vacuum purge air from system through the service port for the stop valve on the outdoor unit After completing procedures above open outdoor unit stop valves stem fully ...

Страница 8: ... Raised Odor trap Grouped piping Make it as large as possible Indoor unit Up to 850 mm 5 Insulate the drain port with insulating material then secure the material with a Main unit Insulating material Insertion margin Matching Drain socket Max 20 m 1 5 2 m Max 150 mm ...

Страница 9: ...terns are available The outdoor unit power supply patterns vary on models S1 S2 L N 1 2 S1 S2 S3 S3 A B C D E F G S1 S2 L N 1 2 S1 S2 S3 1 2 S1 S2 S3 S3 1 2 S1 S2 S3 1 2 S1 S2 S3 D E F G G G G A B C A Outdoor unit power supply B Earth leakage breaker D Outdoor unit F Remote controller G Indoor unit 1 Max 45 m If 2 5 mm2 used Max 50 m If 2 5 mm2 used and S3 separated Max 80 m 2 Max 500 m 2 A Outdoo...

Страница 10: ...the two screws securing the electric component cover and then slide and remove the cover 2 Route the wires along the wiring routes and through the wire inlets in the electric component box cable to the terminal block 4 Secure the wires with the cable straps inside the electric component box Secure the wires with cable straps as cushioning components so that no stress is applied to the connecting s...

Страница 11: ...he i See sensor and signal receiver through the wire inlets in the electric component box as shown in the diagram and around the bushings on secure the grille junction wire and the wires of the i See sensor and signal receiver with the clamp Remove the one screw securing the connector box cover and then open the cover Place the junction wire connector in the connector box Install the wire cover an...

Страница 12: ... 3 Backlight 1 Press the button to stop the air conditioner 2 Press the button The Function setting screen will be displayed and the function No will blink Press the button to change the function No 3 Check that function No 1 is displayed and then press the button Press the button Each time the button is pressed the setting switches between and The temperature is displayed in degrees Celsius The t...

Страница 13: ...on setting Cursor Cursor Request Ref address Mode 1 Mode 2 Mode 3 Mode 4 Grp F1 F2 F3 F4 Function setting Cursor Cursor Request Ref address Mode 7 Mode 8 Mode 9 Mode10 Unit 1 F1 F2 F3 F4 Function setting Ref address Sending data Going to the function select mode Press the button between of 5 seconds Press the Direct the wireless remote controller toward the receiver of the indoor unit and press th...

Страница 14: ...d Silent 08 1 Standard 2 High ceiling 3 Not setting 11 1 Draft less setting vanes angle setup 2 Downward setting vanes angle setup 3 3D i See sensor positioning 3 Position 12 1 Position 2 Position 3 Fan speed during the cooling thermostat is OFF Setting fan speed 27 1 Stop 2 Extra low 3 2 Power failure automatic recovery initial setting depends on the connecting outdoor unit air conditioner Reset ...

Страница 15: ...transmission is completed Make the settings for other outlets following the same procedures No setting Step 3 Draft reduction Step 1 Step 4 All outlets Step 2 Step 5 F1 F2 F3 F4 Manual vane angle Input display Cur Address Check Ref address Unit No Identify unit Check button Change the Unit No in order and check each unit Press the F2 or F3 button to change the Unit No to the unit that you want to ...

Страница 16: ...isplayed only green lights up 00 The test run operation starts and the Test run operation screen is displayed F1 F2 F3 F4 Cool Pipe Auto Switch disp Mode Fan Remain Test run F1 F2 F3 F4 u n e m e c i v r e S r o s r u C u n e m n i a M Test run Input maintenance info Function setting Check Self check F1 F2 F3 F4 Test run menu Cursor Service menu Test run Drain pump test run F1 F2 F3 F4 Remain Vane...

Страница 17: ...efrigerant address is incorrect Blink of operation lamp Check code displayed in the LCD OPERATION IN DICATOR lamp blinking pattern Beep Beep Beep Beep Beep Beep Beep Off Approx 2 5 sec On Approx 3 sec On 0 5 sec On 0 5 sec On 0 5 sec On 0 5 sec Off Approx 2 5 sec On Approx 3 sec On 0 5 sec On 0 5 sec Repeated check code in the following table nth 1st 2nd 3rd 1st 2nd Self check starts Start signal ...

Страница 18: ...with the i See sensor 1 Included when equipped with the wireless remote controller Remote controller holder 1 Included when equipped with the wireless remote controller LR6 AA batteries 2 Included when equipped with the wireless remote controller 3 5 16 tapping screws 2 Included when equipped with the wireless remote controller Turn on the power to the unit at least 12 hours before the test run Pr...

Страница 19: ...in unit Electric component box Grille Ceiling Make sure that there are no gaps Temporarily hanging hooks on the panel relative to the ceiling If the unit is not properly positioned in the ceiling there may rectly 576 576 610 610 to adhere to this range Main unit Ceiling Ceiling opening dimensions to open the intake grille Do not unlatch the hook for the intake grille from the grille as indicated b...

Страница 20: ... orange con nector Make sure that the connector colors match when connecting them Close the connector box cover Connector box cover Connector box Securing screw Junction connector Band corners of the panel and install them and signal receiver in the connector box as shown in the diagram so that there is no slack in the wires and then cut off the panel i See sensor Signal receiver Fastener i See se...

Страница 21: ...th maintenance Return Smooth maintenance Return Smooth maintenance Return Page Page Page COMP current COMP run time COMP On Off COMP frequency A Hz Hr times Hr Ref address Cool Ref address Cool Ref address Cool Sub cool OU TH4 temp OU TH6 temp OU TH7 temp IU air temp IU HEX temp IU filter time press the SELECT button ton and press the SELECT button or F2 button and press the SELECT button Select e...

Отзывы: