A-301
REMOTE CONTROLLER
CEILING
CASSETTE PM
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON
OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN
FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY
DEFROST
FILTER
CHECK TEST
TEMP.
TIMER SET
POWER display
SET TEMPERATURE display
DEFROST display
CHECK display
STANDBY display
TIMER display
CENTRALLY
CONTROLLED display
CLOCK display
OPERATION MODE display
AIR DIRECTION display
AIR SPEED display
FILTER display
Operation lamp
ROOM TEMPERATURE display
display
This lamp lights when the filter need
to be cleaned.
This display lights in the check
mode or when a test operation is
performed.
This lamp lights during operation,
goes off when the unit stops and
flashes when a malfunction occurs.
The temperature of the suction air
is displayed during operation. The
display range is 8
:
to 39
:
. The
display flashes 8
:
when the actual
temperature is less than 8
:
and
flashes 39
:
when the actual tem-
perature is greater than 39
:
.
This lamp lights when electricity is
supplied to the unit.
This displays the selected setting
temperature.
This indicates when the defrost op-
eration is performed.
This indicates when a malfunction
has occurred in the unit which
should be checked.
The [STANDBY] symbol is only dis-
played from the time the heating op-
eration starts unit the heated air be-
gins to blow.
This indicates when the continuous
operation and time operation modes
are set.
It also display the time for the timer
operation at the same time as when
it is set.
This indicates when the unit is con-
trolled by optional features such as
central control type remote con-
troller.
The current time, start time and stop
time can be displayed in ten sec-
ond intervals by pressing the time
switch button. The start time or stop
time is always displayed during the
timer operation.
This indicates the operation mode.
This displays the air direction.
The selected fan speed is displayed.
CHECK MODE
TEST RUN
CAUTION:
●
Only the Power display lights when the unit is stopped and power supplied to the unit.
●
When the central control remote control unit, which is sold separately, is used the ON-OFF button, operation switch button and
TEMP.
adjustment button do not operate.
●
“NOT AVAILABLE” is displayed when the Air speed button are pressed.This indicates that this room unit is not equipped with the fan
direction adjustment function and the louver function.
●
When power is turned ON for the first time, it is normal that “H0” is displayed on the room temperature indication (For max. 2 minutes).
Please wait until this “H0” indication disappear then start the operation.