44
PEAD-RP60GA
PEAD-RP71GA
PEAD-RP100GA
Capacity cord
switch
Model selection
switch
SW2
SW1
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
5
4
3
2
1
OFF
ON
100GA
71GA
60GA
MODELS
<
w
A>
N
L
S1
S2
1 2
2
1
1 2
S3
TO CND
TO OUTDOOR
UNIT
TO CN3C
POWER SUPPLY
~(1PHASE)
230V 50Hz
(IN CASE OF CONNECT
THE REPLACEMENT WIRING)
TO MA-REMOTE
CONTROLLER
DC8.7-13V
TO OUTDOOR UNIT
X6
X5
X4
X1
ZNR
FUSE
P.B.
I.B.
X1
Y
L
W
O
R
N
X6
X5
X4
2
1
(RED)
(WHT)
(WHT)
(YLW)
(WHT)
(WHT)
(WHT)
B
L
U
B
L
U
B
L
U
B
L
U
(BLK)
(WHT)
(RED)
(BLU)
B
L
K
W
H
T
BLK
WHT
(WHT)
(BLU)
B
R
N
BRN
O
R
N
ORN
YLW
(BLU)
(RED)
(ORN)
(RED)
(WHT)
B
L
K
W
H
T
B
L
K
W
H
T
(WHT)
(WHT)
O
R
G
B
L
K
B
L
U
B
L
K
Y
L
W
Y
L
W
G
R
Y
w
A
*
(FACTORY SHIPMENT)
240V
230V
220V
20Pa
60Pa
75Pa
10Pa
50Pa
70Pa
50Pa
35Pa
5Pa
RED
WHT
BLU
CONNECTOR COLOR
2
1
TB5
TB4
S3
S1
S2
2
1
CNP
1
3
3
1
3
1
1
3
CNSK
2 1
CN2S
6
4
3
5
2
1
MF
C
1 2
CN24
3
2
1
1 2 3
1 2
1 2
1 2
TH5
TH2
TH1
LED1
LED2
LED3
1
2
CN2D
CN3C
3
1
CND
CNDK
1
3
7
FAN
5
OFF
ON
SWE
SW2
SW1
CN2L
CN22
CN20
CN21
CN29
CN31
CN90
CN41
CN51
CN32
2
1
1 2 3 4 5 6 7 8 9
4
3
2
1
5
4
3
2
1
INSIDE SECTION OF CONTROL BOX
*External static pressure
RELAY(DRAIN PUMP)
X1
CONNECTOR(WIRELESS)
TRANSMISSION(INDOOR•OUTDOOR)
LED3
POWER SUPPLY(REMOTE CONTROLLER)
LED2
LED1 POWER SUPPLY(I.B.)
CN90
CN51 CONNECTOR(CENTRALLY CONTROL)
CN24 CONNECTOR(HEATER)
VARISTOR
FUSE(T6.3AL250V)
ZNR
FUSE
INDOOR POWER BOARD
P.B.
COND./EVA. TEMP. THERMISTOR
(0
:
/15
t
,25
:
/5.4
t
DETECT)
PIPE TEMP. THERMISTOR/LIQUID
(0
:
/15
t
,25
:
/5.4
t
DETECT)
INTAKE AIR TEMP.THERMISTOR
(0
:
/15
t
,25
:
/5.4
t
DETECT)
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
TERMINAL BLOCK(REMOTE CONTROLLER)
FAN MOTOR
CAPACITOR(FAN MOTOR)
TH5
TH2
TH1
TB4
TB5
MF
C
NAME
NAME
SYMBOL
SYMBOL
NAME
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
SWITCH(CAPACITY CORD)
CONNECTOR(HA TERMINAL-A)
CONNECTOR(REMOTE SWITCH)
INDOOR CONTROLLER BOARD
RELAY(FAN MOTOR)
SWITCH(EMERGENCY OPERATION)
SWITCH(MODEL SELECTION)
CONNECTOR(LOSSNAY)
X6
X5
X4
SWE
SW2
SW1
CN41
CN32
CN2L
I.B.
SYMBOL
Notes:
1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system of
power and signal.
w
1: When work to Supply power separately to indoor and outdoor units was applied, refer to
w
A.
w
2: For power supply system of this unit, refer to the caution label located near this diagram.
OCS07B-2.qxp 07.4.10 0:40 PM Page 44
Содержание Mr.SLIM PKA-RP FAL2
Страница 37: ...37 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Страница 38: ...38 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Страница 66: ...66 9 3 PLA RP AA PLA RP AA2 9 3 1 FRESH AIR INTAKE AMOUNT ...
Страница 67: ...67 9 3 2 BRANCH DUCT Installation at site ...
Страница 77: ...77 PEAD RP60GA PEAD RP71GA ...
Страница 78: ...78 PEAD RP100GA ...
Страница 85: ...85 ...