40
PLA-RP35AA
PLA-RP50AA
PLA-RP60AA
PLA-RP71AA
3
2
1
3
2
1
5
3
1
MF
FAN
(WHT)
RED
WHT
BLK
BLK
X1
X4
X1
X4
C
BCR
3
1
DP
D.U.M
CNP
(BLU)
YLW
YLW
ORN
ORN
YLW
3
1
3
1
3
1
3
1
YLW
YLW
D.HEATER
CNC(RED)
RED
WHT
WHT
BRN
POWER
CNDK
(RED)
POWER
CND
(ORN)
2
1
POWER
CN2D
(WHT)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
3
1
3
1
POWER
CND
(ORN)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
CN41
CN51
CN2L
CN32
9
WIRELESS
CN90
(WHT)
BZ
5
VANE
CN6V
(GRN)
CN2S
(WHT)
CNSK
(RED)
W.B
LED2
CNB
LED1
SW1
SW2
RU
2
1
2
2
1
1
REMOCON
CN22
(BLU)
TB5
TRANSMISSION WIRES
DC12V
TB6
R.B
BLU
BLU
3
2
1
2
1
2
1
D.SENSOR
CN31
(WHT)
INTAKE
CN20
(RED)
HEATER
CN24
(YLW)
LIQUID
CN21
(WHT)
DS
TH2
2
1
PIPE
CN29
(BLK)
TH3
TH1
LED3 LED2 LED1
ON
OFF
SWE
Refer to tables 1
and 2.
SW2
SW1
9 5 10
7
6
3
2
1
8
4
5
MV
5
MV
5
5
MV
5
MV
GRILLE
H2
S1
S2
TB2
TB4
POWER SUPPLY
~(1PHASE)
230V 50Hz
RED
BLU
YLW
ORN
ORN
BRN
GRN/YLW
S3
TB4
TO OUTDOOR UNIT
TO OUTDOOR UNIT
L
S1
S2
S3
N
DC
13.1V
1
2
2
3
1
P.B
ZNR
FUSE
I.B
I.B
YLW
ORN
BRN
ORN
YLW
ORN
W
1 (Fig.1)
Please set the voltage using the
remote controller.
For the setting method. please refer to
the indoor unit Installation Manual.
1 2 3 4 5
ON
OFF
MODELS
Table 1
SW1
Manufacture/Service
PLA-RP. AA
1 2 3 4 5
ON
OFF
MODELS
Table 2
SW2
Manufacture/Service
PLA-RP35AA
PLH-P35AAH
PLA-RP50AA
PLH-P50AAH
PLA-RP60AA
PLH-P60AAH
PLA-RP71AA
PLH-P71AAH
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
PLH-P. AAH
TB2
I.B
HEATER CN24
(YLW)
[PLH-P.AAH models only]
POWER SUPPLY
~(1PHASE)
230V 50Hz
88H
FS1
26H
FS2
H1
L
RED
RED
RED
BLU
GRN/YLW
WHT
WHT
WHT
GRY
N
2
1
2
6
5
1
88H
YLW
YLW
INDOOR POWER BOARD
[LEGEND]
P.B
INDOOR CONTROLLER BOARD
I.B
FUSE(T6.3AL250V)
FUSE
CN2L
VARISTOR
ZNR
CONNECTOR(LOSSNAY)
CN32
FAN CONTROL ELEMENT
BCR
CONNECTOR(REMOTE SWITCH)
CN41
CONNECTOR(HA TERMINAL-A)
CN51
CONNECTOR(CENTRALLY CONTROL)
SW1
SWITCH(MODEL SELECTION)
w
See table 1
SWITCH(CAPACITY CORD)
w
See table 2
SW2
SWE
CONNECTOR(EMERGENCY OPERATION)
X1
RELAY(DRAIN PUMP)
X4
RELAY(FAN MOTOR)
LED1
POWER SUPPLY(I.B)
LED2
POWER SUPPLY(I.B)
LED3
TRANSMISSION(INDOOR-OUTDOOR)
SYMBOL
NAME
SYMBOL
NAME
SYMBOL
NAME
C
CAPACITOR(FAN MOTOR)
MF
FAN MOTOR
MV VANE
MOTOR
DP
DRAIN-UP MACHINE
DS
DRAIN SENSOR
H2
DEW PREVENTION HEATER
TB4
TERMINAL BLOCK (INDOOR/
OUTDOOR CONNECTING LINE)
TB2
TERMINAL BLOCK (HEATER)
w
PLH-P.AAH
models only or option for PLA-RP.AA models.
TB5, TB6
TERMINAL BLOCK(REMOTE
CONTROLLER TRANSMISSION LINE)
TH1
ROOM TEMP.THERMISTOR
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
TH2
PIPE TEMP.THERMISTOR/LIQUID
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
TH5
COND./EVA. TEMP. THERMISTOR
(0
:
/15k
"
,25
:
/5.4k
"
DETECT)
R.B
WIRED REMOTE CONTROLLER BOARD
W.B
HEATER
WIRELESS REMOTE CONTROLLER BOARD
RU
RECEIVING UNIT
FS1
THERMAL FUSE(72
:
, 16A)
FS2
THERMAL FUSE(104
:
, 16A)
H1
HEATER
26H
HEATER THERMAL SWITCH
88H
HEATER CONTACTOR
BZ
BUZZER
LED1
LED(RUN INDICATOR)
LED2
LED(HOT ADJUST)
SW1
SWITCH(HEATING ON/OFF)
SW2
SWITCH(COOLING ON/OFF)
Notes:
1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal
numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit
electric wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification
of 230V), adopting superimposed system of power and signal.
w
1: When work to Supply power separately to indoor and outdoor units was applied,
refer to Fig 1.
w
2: For power supply system of this unit, refer to the caution label located near this diagram.
OCS07B-2.qxp 07.4.10 0:40 PM Page 40
Содержание Mr.SLIM PKA-RP FAL2
Страница 37: ...37 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Страница 38: ...38 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Страница 66: ...66 9 3 PLA RP AA PLA RP AA2 9 3 1 FRESH AIR INTAKE AMOUNT ...
Страница 67: ...67 9 3 2 BRANCH DUCT Installation at site ...
Страница 77: ...77 PEAD RP60GA PEAD RP71GA ...
Страница 78: ...78 PEAD RP100GA ...
Страница 85: ...85 ...