Electric heater

(For  models  with 

heater)

Indoor unit model

PEA

Indoor unit power supply

~/N (single), 50 Hz, 230 V

Indoor unit input capacity
Main switch (Breaker)

*1

16 A

Indoor unit power supply

×

 Min. 1.5

Indoor unit power supply earth

×

 Min. 1.5

Indoor unit-Outdoor unit

*2

×

 Min. 0.3

Indoor unit-Outdoor unit earth

Remote controller-Indoor unit

*3

×

 0.3 (Non-polar)

Indoor unit L-N

*4

AC 230 V

Indoor unit-Outdoor unit S1-S2

*4

Indoor unit-Outdoor unit S2-S3

*4

DC24 V

Remote controller-Indoor unit

*4

DC12 V

6.  Electrical work

If the indoor and outdoor units have separate power supplies, refer to the table at the 

below. If the optional wiring replacement kit is used, change the indoor unit electri-

cal box wiring referring to the figure in the right and the DIP switch settings of the 

outdoor unit control board.

*1. A breaker with at least 3 mm contact separation in each pole shall be provided. Use non-fuse breaker (NF) or earth leakage breaker (NV).
*2. Max. 120 m
*3. The 10 m wire is attached in the remote controller accessory. Max. 500 m

*4. The figures are NOT always against the ground.

Notes:  1.  Wiring size must comply with the applicable local and national code.

 

2.  Power supply cords and indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 245 IEC 57)

 

3.  Install an earth longer than other cables.

Circuit 

rating

Wiring

Wire No. 

×

 size 

(mm

2

)

Connectors (connections when shipped 
from the factory are for indoor unit power 
supplied from outdoor unit)

Indoor  unit  power  supplied  from  outdoor  unit 

(when shipped from factory)

If the indoor and 
outdoor units have 
separate power 
supplies, change the 
connections of the 
connectors as shown 
in the following 

figure.

Connectors

Indoor unit 

control board

Separate indoor unit/outdoor unit power 
supplies

Electric heater

(For  models  with 

heater)

Indoor unit 

control board

6.3.  Separate indoor unit/outdoor unit power supplies (For PUHZ application only)

The following connection patterns are available.

The outdoor unit power supply patterns vary on models.

<For models without heater>

*  The indoor power supply terminal kit is required.

*  Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.

*  Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.

A

 Outdoor unit power supply

B

 Earth leakage breaker

C

 Wiring circuit breaker or isolating switch

D

 Outdoor unit

E

 Indoor unit/outdoor unit connecting cords

F

 Wired remote controller (optional parts)

G

 Indoor unit

H

 Option

J

 Indoor unit power supply

A

 Outdoor unit power supply

B

 Earth leakage breaker

C

 Wiring circuit breaker or isolating switch

D

 Outdoor unit

E

 Indoor unit/outdoor unit connecting cords

F

 Wired remote controller (optional parts)

G

 Indoor unit

H

 Option

J

 Indoor unit power supply

<For models without heater>

*  The indoor power supply terminal kits are required.

Indoor unit specifications

Indoor power supply terminal kit (option)

Required

Indoor unit electrical box connector connec-

tion change

Required

Label affixed near each wiring diagram for 

the indoor and outdoor units

Required

Outdoor unit DIP switch settings (when us-

ing separate indoor unit/outdoor unit power 

supplies only)

*  There are three types of labels (labels A, B, and C). Affix the appropriate labels 

to the units according to the wiring method.

1:1 System

Simultaneous twin/triple/four system

RG79D318H02.indd   8

12/6/2010   1:26:44 PM

Содержание Mr.Slim PEA-RP-EAQ

Страница 1: ...STALLATION MANUAL For safe and correct use read this manual and the outdoor unit installation manual thoroughly before installing the air conditioner unit Air Conditioners PEA RP EAQ FOR INSTALLER English ...

Страница 2: ...garding the appro priate measures to prevent the allowable concentration from being exceeded Should the refrigerant leak and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result Ventilate the room if refrigerant leaks during operation If refrigerant comes into contact with a flame poisonous gases will be released All electric work must be performed by a...

Страница 3: ...akdown may result 1 2 Before installation relocation Caution Be extremely careful when transporting the units Two or more persons are needed to handle the unit as it weighs 20 kg or more Do not grasp the pack aging bands Wear protective gloves to remove the unit from the packaging and to move it as you can injure your hands on the fins or other parts Be sure to safely dispose of the packaging mate...

Страница 4: ...en beams for suspending air conditioners must be sturdy and their sides must be at least 6 cm long if the beams are separated by not more than 90 cm and their sides must be at least 9 cm long if the beams are separated by as much as 180 cm The size of the suspension bolts should be ø10 3 8 The bolts do not come with the unit 2 Ferro concrete structures Secure the suspension bolts using the method ...

Страница 5: ... pipes are used wrap liquid and gas pipes with commercially available insulation materials heat resistant to 100 C or more thickness of 12 mm or more The indoor parts of the drain pipe should be wrapped with polyethylene foam insula tion materials specific gravity of 0 03 thickness of 9 mm or more Apply thin layer of refrigerant oil to pipe and joint seating surface before tightening flare nut Use...

Страница 6: ...ecting cable Use buffer bushing to prevent tensile force to the terminal bed F The Indoor Outdoor connecting cables G Tensile force H Knockout hole for the remote controller cables Use ordinary bushing I The remote controller cables Selecting non fuse breaker NF or earth leakage breaker NV 4 Installing the refrigerant piping 4 3 Refrigerant and drainage piping locations of indoor unit Fig 4 3 A Re...

Страница 7: ...are not electrically insulated by the transformer or other device Notes 1 Wiring size must comply with the applicable local and national code 2 Power supply cords and indoor unit outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord Design 245 IEC 57 3 Install an earth longer than other cables For models without heater For models with heater For models with...

Страница 8: ...ve separate power supplies change the connections of the connectors as shown in the following figure Connectors Indoor unit control board Separate indoor unit outdoor unit power supplies Electric heater For models with heater Indoor unit control board 6 3 Separate indoor unit outdoor unit power supplies For PUHZ application only The following connection patterns are available The outdoor unit powe...

Страница 9: ...oltage setting Be sure to change the power voltage setting depending on the voltage used 1 Go to the function setting mode Switch OFF the remote controller Press the A and B buttons simultaneously and hold them for at least 2 seconds FUNCTION will start to flash 2 Use the C button to set the refrigerant address 3 to 00 3 Press D and will start to flash in the unit number 4 display 4 Use the C butt...

Страница 10: ...set to OFF record the settings and then set all of the switches to OFF Begin recovering the refrigerant After moving the unit to a new location and completing the test run set the SW5 switches to the previously recorded settings Unit replacement operation When reusing existing pipes that carried R22 refrigerant replacement opera tion must be performed before performing a test run If new pipes are ...

Страница 11: ... Check code F Unit address Fig 8 2 8 Test run OPERATION INDICATOR lamp flash pattern Beep Beep Beep Beep Beep Beep Beep Off Approx 2 5 sec On Approx 3 sec On 0 5 sec On 0 5 sec On 0 5 sec On 0 5 sec Off Approx 2 5 sec On Approx 3 sec On 0 5 sec On 0 5 sec Repeated Number of flashes beeps in pattern indicates the check code in the following table i e n 5 for P5 Number of flashes beeps in pattern in...

Страница 12: ...gnal was received and the OPERATION INDICATOR lamp does not come on there are no error records 2 If the beeper sounds three times continuously beep beep beep 0 4 0 4 0 4 sec after the initial two beeps to confirm the self check start signal was received the specified refrigerant address is incorrect On wired remote controller Check code displayed in the LCD If the unit cannot be operated properly ...

Страница 13: ...ation frequency can be fixed and the operation can be stabilized If the air conditioner is stopped use the following procedure to start this operation Stable cooling operation Stable heating operation Stable operation cancellation Display A Press the button to select the operation mode Press the button Waiting for stable operation Display D Stable operation 10 20 min You can check the data using s...

Страница 14: ......

Страница 15: ......

Страница 16: ... 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand RG79D318H02 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC ...

Отзывы: