CHECKING AFTER INSTALLATION

After finishing the installation, check the following items again by marking  .

Have special circuits been provided?
Is power supply voltage as specified?
Has indoor/outdoor connecting wire been inserted into terminal block?
Has indoor/outdoor connecting wire been secured firmly?
Has intermediary connection between power cable and indoor/outdoor connecting wire been carried out?
Is combination of connection pipes and indoor/outdoor connecting wire correct (Room A, Room B)?
Is ground cable connection correct?
Has leak test been carried out?
Has air purge been carried out?
Is stop valve fully open?
Has drain discharge been checked?
Is insulation over connection pipe joints correct?
Is strength of installation location well enough?
Have all of 

 WARNING and 

 CAUTION items in “1. THE FOLLOWING SHOULD ALWAYS BE OB-

SERVED FOR SAFETY” been checked?

5-8

GAS CHARGE

Perform gas charge to unit.

1

Connect gas cylinder to the service port of stop valve.

2

Perform air purge of the pipe (or hose) coming from refrigerant gas cylinder.

3

Replenish specified amount of the refrigerant, while operating the air conditioner for cooling.

Note:
In case of adding refrigerant, comply with the quantity specified for the refrigerating cycle.

 CAUTION:

When charging the refrigerant system with additional refrigerant, be sure to use liquid refrigerant. Add-
ing gas refrigerant may change the composition of the refrigerant in the system and affect normal
operation of the air conditioner. Also, charge the system slowly, otherwise the compressor will be
locked.

Indoor

unit

Union

Stop valve

Outdoor

unit

Union

Gauge manifold
valve (for R410A)

Charge hose (for R410A)

Refrigerant gas
cylinder
operating valve
(for R410A)

Refrigerant gas cylinder
for R410A with siphon

Refrigerant (liquid)

Electronic scale for
refrigerant charging

Liquid pipe

Gas pipe

Union

Stop valve with

service port

Union

(MXZ-2A20NA)

To maintain the high pressure of the gas cylinder, warm the gas cylinder with warm water (under 140°F) during
cold season. But never use naked fire or steam.

5-9

TEST RUN

• Be sure to perform the test run for each unit. Make sure each indoor unit operates properly following the

installation manual attached to the unit.

• If you perform the test run for all indoor units at once, you cannot detect any erroneous connection, if any, of

the refrigerant pipes and the indoor/outdoor unit connecting wires.

About the restart protective mechanism

Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3
minutes to protect the air conditioner.

5-10 EXPLANATION TO THE  CUSTOMER

• Recommend the customer to read the OPERATING INSTRUCTIONS carefully.
• Using the OPERATING INSTRUCTIONS for each unit, explain the following to the customer, how to control

temperature, how to remove the air filters, how to remove or put the remote controller in the remote controller
holder, how to clean, precautions for operation, etc.

If the customer (user) is absent, explain to the purchaser (owner, building’s controller, etc) about those
points.

Содержание Mr.Slim MXZ-2A20NA

Страница 1: ...TIONERS Model INSTALLATION MANUAL MXZ 2A20NA FLARE CONNECTION TYPE ATTENTION This manual mentions how to install only the outdoor unit MXZ 2A20NA As for the way of installation for indoor unit MSZ A09NA MSZ A12NA and MSZ A15NA please refer to the installation manual being attached each indoor unit The installation manual details the suggested installation method Any structural alterations necessar...

Страница 2: ...mplete connecting and fixing could cause fire Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet It could cause a fire or an electric shock due to de fective contact defective insulation exceeding the permissible current etc Check that the refrigerant gas due not leak after installation has completed If refrigerant gas leaks ...

Страница 3: ...required for the affected device Install the unit horizontally Please install it in an area not affected by snowfall or blowing snow In areas with heavy snow please install a canopy a pedestal and or some baffle boards Note It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there WARNING Be sure to install the unit in a place that well sustains its w...

Страница 4: ... supply circuit between indoor and outdoor unit depending on local code FREE SPACE REQUIRED AROUND OUTDOOR UNIT Unit mm inch 350 13 78 or more 100 3 94 or more 1 Top side obstacles When there is an obstacle behind the rear side only it does not matter if there is an obstacle over the top side as shown in the figure below 2 Front blowing side open As long as space like the one shown in the figure c...

Страница 5: ...2 tools be used Description Gauge manifold No R410A has high pressures beyond the measurement range of existing gauges Charge hose No Hose material and cap size have been changed to improve the pressure resist ance Gas leak detector No Dedicated for HFC refrigerant Torque wrench Yes 1 4 and 3 8 No 1 2 Flare tool Yes Clamp bar hole has been enlarged to reinforce the spring strength in the tool Flar...

Страница 6: ...it For tightening use the same tightening torque applied for indoor unit and tighten the flare nut with torque wrench or spanner INSULATION AND TAPING 1Cover piping joints with pipe cover 2For outdoor unit side surely insulate every piping including valves 3Using piping tape E apply taping starting from the entry of outdoor unit Fix the end of piping tape E with adhesive tape When piping has to be...

Страница 7: ...ated fully open all stop valves on both sides of gas pipe and liquid pipe Operating without fully opening lowers the performance and this causes trouble Tighten the cap to the service port to obtain the initial status Retighten the cap Leak test or the vacuum pump with the function to prevent the back flow Gauge manifold valve for R410A Pressure gauge for R410A Compound pressure gauge for R410A 0 ...

Страница 8: ... in the system and affect normal operation of the air conditioner Also charge the system slowly otherwise the compressor will be locked Indoor unit Union Stop valve Outdoor unit Union Gauge manifold valve for R410A Charge hose for R410A Refrigerant gas cylinder operating valve for R410A Refrigerant gas cylinder for R410A with siphon Refrigerant liquid Electronic scale for refrigerant charging Liqu...

Страница 9: ...S DE AIRE DE TIPO DIVIDIDO Modelo MANUAL DE INSTALACIÓN MXZ 2A20NA TIPO DE CONEXIÓN ABOCARDADA ATENCIÓN Este manual corresponde únicamente a la instalación de la uni dad exterior MXZ 2A20NA Para la instalación de las unidades interiores MSZ A09NA MSZ A12NA y MSZ A15NA consulte el manual de instalación que se incluye en cada unidad interior El manual de instalación detalla el método de instalación ...

Страница 10: ...sas podrían provocar un in cendio No emplee conexiones intermedias del cable de alimen tación ni tampoco un cable alargador evite también co nectar demasiados aparatos a una sola toma de CA Esto podría provocar un incendio o una descarga eléctrica a causa de un contacto o un aislamiento defectuoso un exce so de corriente etc Una vez acabada la instalación compruebe que no haya una fuga de gas refr...

Страница 11: ...or sea baja observe las instruc ciones siguientes No instale nunca la unidad exterior en un lugar en el que el lado de entrada salida de aire quede expuesto directamente al viento Para evitar la exposición al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposición al viento se recomienda instalar una placa deflectora en el lado de salida de aire de...

Страница 12: ...de alimentación entre las unidades interior y exterior depen diendo de la normativa local ESPACIO LIBRE NECESARIO ALREDEDOR DE LA UNIDAD EXTERIOR unidad mm pulg 350 13 78 o más 100 3 94 o más 1 Obstáculos en la parte superior Cuando hay un obstáculo en la parte trasera no importa si hay algún obstáculo por encima de la unidad tal y como se muestra en la siguiente ilus tración 2 Parte delantera ven...

Страница 13: ...IA DE ALTURA Límites 2A20NA Longitud de tubería por unidad interior 25 m 82 pies máx Longitud total de tubería por multisistema 50 m 164 pies máx Diferencia de altura 10 m 33 pies máx N º encorvaduras por unidad interior 25 máx N º total encorvaduras por multisistema 50 máx Ajuste de refrigerante Si la longitud de la tubería es superior a 40 m 131 pies será necesario emplear más refrigerante R410A...

Страница 14: ...rior Para el apriete utilice el mismo par aplicado en la unidad interior y apriete la tuerca abocardada con una llave dinamométrica o una llave de tuercas AISLAMIENTO TÉRMICO Y FORRADO CON CINTA 1Cubra las uniones de tuberías con cubiertas de tubería 2En el lado de la unidad exterior aísle bien cada una de las tuberías y válvulas 3Aplique cinta de tuberías E a partir de la entrada de la unidad ext...

Страница 15: ...a por completo todas las válvulas de retención de ambos lados del tubo de gas y del tubo de líquido Si no se lleva a cabo esta operación abriendo dichas válvulas por completo el rendi miento disminuirá y se producirán problemas Apriete la tapa del puerto de servicio para volver al estado inicial Vuelva a apretar la tapa Prueba de fugas o la bomba de vacío con la función de evitar el reflujo Válvul...

Страница 16: ...de alterarse en el siste ma y afectar al funcionamiento normal del aparato de aire acondicionado Recuerde también cargar el sistema poco a poco ya que de lo contrario puede bloquear el compresor Unidad interior Unión Válvula de retención Unidad exterior Unión Válvula colectora de manómetro para R410A Manguera de carga para R410A Válvula de accionamiento del cilindro de gas refrigerante para R410A ...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79Y666H01 ...

Отзывы: