2. INSTALLATION DIAGRAM & ACCESSORIES

1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR

SAFETY

More than 100 mm
(3.94 in.)

Open as a rule
More than 500 mm (19.69 in.)
if the front and both sides are
open

More than 100 mm (3.94 in.)
More than 200 mm (7.87 in.)
if there are obstacles to both
sides

Open as a rule
More than 500 mm
(19.69 in.) if the back,
both sides and top are
open

More than 350 mm (13.78 in.)

Note:
The dimensions given along the arrows above are required to guarantee
the air conditioner’s performance. Install the unit in as wide a place as
possible for later service or repairs.

Before installation

This installation manual is only for the outdoor unit installation. In installing the indoor units, refer to the
installation manual attached to each indoor unit.
Any structural alternations necessary for the installation must comply with the local building code require-
ments.

 CAUTION

Perform grounding.

Do not connect the ground wire to a gas pipe, water
pipe, lightning rod or telephone ground wire. De-
fective grounding could cause an electric shock.

Do not install the unit in a place where an in-
flammable gas leaks.

If gas leak and accumulate in the area surround-
ing the unit, it could cause an explosion.

Fasten a flare nut with a torque wrench as
specified in this manual.

When fastened too tight, a flare nut may broken after
a long period and cause a leakage of refrigerant.

Install a ground leakage breaker depending
on the installation place (Where it is humid).

If a ground leakage breaker is not installed, it
could cause an electric shock.

Perform the drainage/piping work securely
according to the installation manual.

If there is a defect in the drainage/piping work,
water could drop from the unit and household
goods could be wet and damaged.

Do not install the unit by yourself (customer).

Incomplete installation could cause injury due to
fire, electric shock, the unit falling or leakage of
water. Consult the dealer from whom you pur-
chased the unit or special installer.

Install the unit securely in a place which can
bear the weight of the unit.

When installed in an insufficient strong place, the
unit could fall causing injury.

Use the specified wires to connect the indoor
and outdoor units securely and attach the
wires firmly to the terminal block connecting
sections so the stress of the wires is not ap-
plied to the sections.

Incomplete connecting and fixing could cause fire.

Do not use intermediate connection of the
power cord or the extension cord and do not
connect many devices to one AC outlet.

It could cause a fire or an electric shock due to de-
fective contact, defective insulation, exceeding the
permissible current, etc.

Check that the refrigerant gas due not leak
after installation has completed.

If refrigerant gas leaks indoors, and comes into
contact with the fire of a fan heater, space heater,
stove, etc., harmful substances will be generated.

Perform the installation securely referring to
the installation manual.

Incomplete installation could cause a personal
injury due to fire, electric shock, the unit falling or
leakage of water.

Perform electrical work according to the in-
stallation manual and be sure to use an ex-
clusive circuit.

If the capacity of the power circuit is insufficient
or there is insufficient electrical work, it could re-
sult in a fire or an electric shock.

Attach the electrical cover to the indoor unit and
the service panel to the outdoor unit securely.

If the electrical cover in the indoor unit and/or the
service panel in the outdoor unit are not attached
securely, it could result in a fire or an electric
shock due to dust water, etc.

Be sure to use the part provided or specified
parts for the installation work.

The use of defective parts could cause an injury
due to a fire, an electric shock, the unit falling,
leakage of water, etc.

Be sure to cut off the main power in case of
setting up the indoor electronic control P.C.
board or wiring works.

It could cause an electric shock.

The appliance shall be installed in accordance
with national wiring regulations.

When installing or relocating the unit, make
sure that no substance other than the speci-
fied refrigerant (R410A) enters the refrigerant
circuit.

Any presence of foreign substance such as air
can cause abnormal pressure rise or an explo-
sion.

• Please report to your supply authority or obtain their consent before connecting this equipment to

the power supply system.

• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing

the air conditioner.

• Be sure to observe the cautions specified here as they include important items related to safety.
• The indications and meanings are as follows.

 WARNING: Could lead to death, serious injury, etc.

 CAUTION: Could lead to serious injury in particular environments when operated incorrectly.

• After reading this manual, be sure to keep it together with the INSTRUCTION MANUAL in a handy

place on the customer’s site.

 WARNING

Содержание Mr.Slim MXZ-2A20NA

Страница 1: ...TIONERS Model INSTALLATION MANUAL MXZ 2A20NA FLARE CONNECTION TYPE ATTENTION This manual mentions how to install only the outdoor unit MXZ 2A20NA As for the way of installation for indoor unit MSZ A09NA MSZ A12NA and MSZ A15NA please refer to the installation manual being attached each indoor unit The installation manual details the suggested installation method Any structural alterations necessar...

Страница 2: ...mplete connecting and fixing could cause fire Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet It could cause a fire or an electric shock due to de fective contact defective insulation exceeding the permissible current etc Check that the refrigerant gas due not leak after installation has completed If refrigerant gas leaks ...

Страница 3: ...required for the affected device Install the unit horizontally Please install it in an area not affected by snowfall or blowing snow In areas with heavy snow please install a canopy a pedestal and or some baffle boards Note It is advisable to make a piping loop near outdoor unit so as to reduce vibration transmitted from there WARNING Be sure to install the unit in a place that well sustains its w...

Страница 4: ... supply circuit between indoor and outdoor unit depending on local code FREE SPACE REQUIRED AROUND OUTDOOR UNIT Unit mm inch 350 13 78 or more 100 3 94 or more 1 Top side obstacles When there is an obstacle behind the rear side only it does not matter if there is an obstacle over the top side as shown in the figure below 2 Front blowing side open As long as space like the one shown in the figure c...

Страница 5: ...2 tools be used Description Gauge manifold No R410A has high pressures beyond the measurement range of existing gauges Charge hose No Hose material and cap size have been changed to improve the pressure resist ance Gas leak detector No Dedicated for HFC refrigerant Torque wrench Yes 1 4 and 3 8 No 1 2 Flare tool Yes Clamp bar hole has been enlarged to reinforce the spring strength in the tool Flar...

Страница 6: ...it For tightening use the same tightening torque applied for indoor unit and tighten the flare nut with torque wrench or spanner INSULATION AND TAPING 1Cover piping joints with pipe cover 2For outdoor unit side surely insulate every piping including valves 3Using piping tape E apply taping starting from the entry of outdoor unit Fix the end of piping tape E with adhesive tape When piping has to be...

Страница 7: ...ated fully open all stop valves on both sides of gas pipe and liquid pipe Operating without fully opening lowers the performance and this causes trouble Tighten the cap to the service port to obtain the initial status Retighten the cap Leak test or the vacuum pump with the function to prevent the back flow Gauge manifold valve for R410A Pressure gauge for R410A Compound pressure gauge for R410A 0 ...

Страница 8: ... in the system and affect normal operation of the air conditioner Also charge the system slowly otherwise the compressor will be locked Indoor unit Union Stop valve Outdoor unit Union Gauge manifold valve for R410A Charge hose for R410A Refrigerant gas cylinder operating valve for R410A Refrigerant gas cylinder for R410A with siphon Refrigerant liquid Electronic scale for refrigerant charging Liqu...

Страница 9: ...S DE AIRE DE TIPO DIVIDIDO Modelo MANUAL DE INSTALACIÓN MXZ 2A20NA TIPO DE CONEXIÓN ABOCARDADA ATENCIÓN Este manual corresponde únicamente a la instalación de la uni dad exterior MXZ 2A20NA Para la instalación de las unidades interiores MSZ A09NA MSZ A12NA y MSZ A15NA consulte el manual de instalación que se incluye en cada unidad interior El manual de instalación detalla el método de instalación ...

Страница 10: ...sas podrían provocar un in cendio No emplee conexiones intermedias del cable de alimen tación ni tampoco un cable alargador evite también co nectar demasiados aparatos a una sola toma de CA Esto podría provocar un incendio o una descarga eléctrica a causa de un contacto o un aislamiento defectuoso un exce so de corriente etc Una vez acabada la instalación compruebe que no haya una fuga de gas refr...

Страница 11: ...or sea baja observe las instruc ciones siguientes No instale nunca la unidad exterior en un lugar en el que el lado de entrada salida de aire quede expuesto directamente al viento Para evitar la exposición al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposición al viento se recomienda instalar una placa deflectora en el lado de salida de aire de...

Страница 12: ...de alimentación entre las unidades interior y exterior depen diendo de la normativa local ESPACIO LIBRE NECESARIO ALREDEDOR DE LA UNIDAD EXTERIOR unidad mm pulg 350 13 78 o más 100 3 94 o más 1 Obstáculos en la parte superior Cuando hay un obstáculo en la parte trasera no importa si hay algún obstáculo por encima de la unidad tal y como se muestra en la siguiente ilus tración 2 Parte delantera ven...

Страница 13: ...IA DE ALTURA Límites 2A20NA Longitud de tubería por unidad interior 25 m 82 pies máx Longitud total de tubería por multisistema 50 m 164 pies máx Diferencia de altura 10 m 33 pies máx N º encorvaduras por unidad interior 25 máx N º total encorvaduras por multisistema 50 máx Ajuste de refrigerante Si la longitud de la tubería es superior a 40 m 131 pies será necesario emplear más refrigerante R410A...

Страница 14: ...rior Para el apriete utilice el mismo par aplicado en la unidad interior y apriete la tuerca abocardada con una llave dinamométrica o una llave de tuercas AISLAMIENTO TÉRMICO Y FORRADO CON CINTA 1Cubra las uniones de tuberías con cubiertas de tubería 2En el lado de la unidad exterior aísle bien cada una de las tuberías y válvulas 3Aplique cinta de tuberías E a partir de la entrada de la unidad ext...

Страница 15: ...a por completo todas las válvulas de retención de ambos lados del tubo de gas y del tubo de líquido Si no se lleva a cabo esta operación abriendo dichas válvulas por completo el rendi miento disminuirá y se producirán problemas Apriete la tapa del puerto de servicio para volver al estado inicial Vuelva a apretar la tapa Prueba de fugas o la bomba de vacío con la función de evitar el reflujo Válvul...

Страница 16: ...de alterarse en el siste ma y afectar al funcionamiento normal del aparato de aire acondicionado Recuerde también cargar el sistema poco a poco ya que de lo contrario puede bloquear el compresor Unidad interior Unión Válvula de retención Unidad exterior Unión Válvula colectora de manómetro para R410A Manguera de carga para R410A Válvula de accionamiento del cilindro de gas refrigerante para R410A ...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79Y666H01 ...

Отзывы: