44
OPERATING PROCEDURE
PHOTOS
4. Removing the horizontal vane motor unit
(1) Remove the horizontal vane and the panel. (Refer to 1.)
(2) Remove the screws of the horizontal vane motor unit, and
pull out the horizontal vane motor unit. (Photo 5)
(3) Disconnect the connector from the horizontal vane motor
unit.
Photo 5
5. Removing the indoor fan motor and the line flow fan
(1) Remove the horizontal vane, the panel (refer to 1.) and the
corner box.
(2) Remove the switch holder and the electrical box. (Refer to 3.)
(3) Pull out the drain hose from the nozzle assembly, and
remove the nozzle assembly.
(4) Remove the screws fixing the motor bed. (Photo 6)
(5) Loosen the screw fixing the line flow fan. (Photo 7)
(6) Remove the motor bed together with fan motor and motor
band.
(7) Release the hooks of the motor band, and remove the
motor band then pull out the indoor fan motor.
(8) Remove the screws fixing the left side of the heat exchang-
er. (Photo 8)
(9) Lift the heat exchanger, and pull out the line flow fan to the
lower-left.
Photo 6
Photo 7
Photo 8
Screws of the
left side of the
heat exchanger
Screw of
the line flow
fan
Screws of the
horizontal vane
motor unit
Screws of
the motor
bed
Motor band
Содержание Mr.Slim MSZ-GC22NA - C1
Страница 7: ...7 MSZ GC22NA MSZ GC25NA MSZ GC35NA C1 MSZ GC35NA C2 4 WIRING DIAGRAM ...
Страница 8: ...8 MSZ GC50NA MSZ GC60NA MSZ GC71NA ...
Страница 47: ...47 ...