10
6-1. TIMER SHORT MODE
For service, set time can be shortened by short circuit of JPG and JPS on the indoor electronic control P.C. board.
The time will be shortened as follows. (Refer to 8-7.)
Set time : 1-minute
→
1-second
Set time : 3-minute
→
3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by short circuit-of JPG and JPS.)
6-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below :
NOTE
: For modification, take out
the batteries and press
the OPERATE/STOP (ON/
OFF) button twice or 3
times at first.
After finish modification,
put back the batteries then
press the RESET button.
J2
J1
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit only accept the signal from the remote controller that has been assigned to the indoor unit once they are set.
The setting will be cancelled if the breaker has turned OFF, or the power supply has shut down.
Please conduct the above setting once again after the power has restored.
The P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
Table 1
1 unit operation
2 units operation
3 units operation
4 units operation
No. 1 unit
No modi
fi
cation
Same as at left
Same as at left
Same as at left
No. 2 unit
–
Solder J1
Same as at left
Same as at left
No. 3 unit
–
–
Solder J2
Same as at left
No. 4 unit
–
–
–
Solder both J1 and J2
MSZ-GC22NA MSZ-GC25NA MSZ-GC35NA MSZ-GC50NA MSZ-GC60NA MSZ-GC71NA
6
SERVICE FUNCTIONS
Содержание Mr.Slim MSZ-GC22NA - C1
Страница 7: ...7 MSZ GC22NA MSZ GC25NA MSZ GC35NA C1 MSZ GC35NA C2 4 WIRING DIAGRAM ...
Страница 8: ...8 MSZ GC50NA MSZ GC60NA MSZ GC71NA ...
Страница 47: ...47 ...