Symptom

Cause/Remedy

Troubleshooting

E

Check to see if the unit is on a slope or uneven surface.

Move to a sturdy even surface.

P5

Check to see if the pre-fi lter is clogged.

Clean according to the maintenance procedures.

P22

Operating the unit in small rooms or in tight spaces sometimes causes 
the sound to reverberate.

Place a mat underneath the unit.

P7

The sound increases when the compressor activates (approximately 3 minutes 
after turning on the unit or during EASY DEHUMIDIFYING or AUTO).

The volume of the sound differs depending on the angle of the louvre.

P16

This is the sound of the refrigerant. The sound can be heard while the refrigerant 
stabilizes after the unit turns on, changes modes, or stops.

This is the sound of the compressor. In modes that monitor the humidity 
level or during drying inside, the compressor operates intermittently 
causing the sound to be heard occasionally. The compressor does not 
activate after turning the unit off, or for 3 minutes after plugging the unit 
into a power socket. (This is to protect the compressor from damage.)

P12

The unit 
makes 
noises

The operating 
noise is loud/
reverberates

The operating 
sound suddenly 
increases in 
volume 

The wind sound 
changes in volume

The unit produces 
a simmering sound 

The unit produces 
a buzz that sounds 
intermittently (or 
the compressor 
does not activate)

When fi rst used 

The heat converter heats rapidly causing an odour. This is not a malfunction.

The moisture expelled from inside the unit may smell due to odorants that 
were not caught by the silver ion fi lter dissolving in the water. This is not a 
malfunction.

The unit 
produces 
an odour

During internal 
drying
During 
deodorizing 
clothes operation

Error message (Humidity indicator)

Digital display

Cause/Remedy

Check to see if anything is blocking the air outlet.

Remove the obstruction, and plug the power cord into the power 
socket again.

P5~10

Check to see if the pre-fi lter is clogged.

Clean according to the maintenance procedures.

P22

 appears in the CURRENT 

HUMIDITY indicator

Malfunction

Take note of error message, unplug the power cord, and contact the 
place of purchase.

~

 appears in the 

CURRENT HUMIDITY 
indicator

If the symptoms persist even after following the prescribed remedies, or the error message does not 
disappear, unplug the power cord, and contact the place of purchase.

Stop operation and contact the place of purchase.

The power plug or power 
socket generates abnormal 
heat

 appears in the 

CURRENT HUMIDITY indicator

Check to see if the power cord is plugged into the power socket properly.

Plug the power cord into the power socket properly.

P10

e̲mj̲e26cx̲h.indb   25

e̲mj̲e26cx̲h.indb   25

2009/10/26   17:22:25

2009/10/26   17:22:25

Содержание MJ-E26CX-H

Страница 1: ...13 HIGH LOW LOW TEMP 14 Using Child Lock 14 Reducing Growth of Mildew in Bathroom Bathroom Mildew Guard 15 Using Louvre 16 Using Timer 17 Removing Odor from Clothes Clothes Deodorant 18 Drying Inside Operation 19 Draining 20 Continuous Drainage 21 Troubleshooting Maintenance 22 Replacement Parts 23 Storage and Disposal 23 Troubleshooting 24 Specifications 26 In order to ensure correct usage please...

Страница 2: ...about mildew in the bathroom BATHROOM MILDEW GUARD P 15 DEO DRY P 18 When you want to perform automatic operation EASY DEHUMIDIFYING P 12 When you want to perform continuous operation HIGH P 14 Reducing blowing sound and performing continuous operation LOW P 14 When you want to perform automatic operation INTELLIGENT LAUNDRY P 12 When you want to perform continuous operation HIGH P 14 ...

Страница 3: ...s close to freezing disabling the dehumidifier and only the blower is operational z The amount of dehumidifying becomes less in winter When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect of the dehumidifier is greatly reduced as shown in the graph below Although only a little water collects in the t...

Страница 4: ...nit near heat generating devices such as stoves fan heaters etc The plastic parts may melt and cause fire Do not put your fingers or any long object into the air intake outlet Do not touch the swing louvre The internal fan rotates at high speeds and such actions may result in injury or malfunctions Do not attempt to repair disassemble or modify the unit This may result in fire and or electric shoc...

Страница 5: ...fic works This may negatively affect the quality of the items stored Do not point airflow from the unit directly at the body for a prolonged period of time Be especially careful when using the unit where there is someone who is unable to adjust the humidity infant child or elderly person If air flow is directed at the body for long periods it may harm one s physical condition and lead to dehydratio...

Страница 6: ...k are vulnerable to dry air as it may cause cracks and warping Keep the unit always in an upright position Inclining the unit may cause water in the tank to leak into the unit resulting in malfunction Should you incline the unit accidentally contact the place of purchase for advice Do not carry the unit horizontally This may result in malfunctions Such malfunctions are NOT covered under warranty N...

Страница 7: ...ouvre P16 Tank lid P10 20 Tank Guard P10 20 Floating Element P20 Water Tank P10 20 Level window Downward Air Outlet Rear Air Intake Silver ion filter P22 23 Pre filter P22 Storage Hook Cord Tie Remove during operation At least 20 cm At least 50 cm At least 20 cm At least 20 cm At least 20 cm Installing your dehumidifier Make sure to leave some space around the unit Operating noise Use the unit on ...

Страница 8: ... Lights when the drying inside operation is waiting to begin DRYING INSIDE switch Use this to switch the internal drying operation ON and OFF SWING LOUVRE Switch Sets the swing louvre direction or locks it into position POWER lamp Lights during operation POWER switch Turns the power ON OFF P12 MODE Switch Switches the operating mode HUMIDITY SELECTION Switch Sets the humidity P13 15 Lamps The lamp...

Страница 9: ...ions Low Temperature Indicator Defrost Indicator High Humidity Warning If the room temperature drops to approximately 15 C or lower during operation is indicated to notify you Activating LOW TEMP mode is recommended when is indicated P14 When is indicated blowing dehumidifying is stopped and the frost that has accumulated inside melts and drops into the tank Please wait a while as operation will r...

Страница 10: ...k lid Tank guard Make sure the tank is inserted correctly Tank Make sure the tank is not broken or cracked Plug the power cord into the power socket Use a 220 240V AC power socket only The current humidity is indicated If the louvre is open it closes automatically Carrying the Unit The unit can be transported using the wheels on the bottom Check that the water tank is empty and the louvre is shut ...

Страница 11: ...mately 5 cm Hang any difficult to dry items in positions where wind can easily come into contact with them Clothes placed close together will take time to dry Drying takes a long time in the following cases When there are a lot of clothes When the room temperature is low P3 The drying time required at a low temperature approximately 10 C is around twice that at a normal temperature approximately 2...

Страница 12: ...nto the power socket This is in order to protect the compressor Dehumidifying begins approximately 3 minutes after you press the POWER switch When dehumidifying begins the operational noise increases The unit remembers the operating mode Even if the plug is disconnected or the power turned off the unit restarts at the previous setting EASY DEHUMIDIFYING The unit operates intermittently controlling...

Страница 13: ...ROOM MILDEW GUARD P15 AUTO When you want to set the humidity and perform dehumidifying 1 2 1 Press P12 2 Press to select the operating mode A border is displayed around AUTO Information You can also switch to AUTO with the MODE switch To stop operation Press P12 AUTO The unit changes the airflow rate automatically and operates intermittently to maintain the set humidity If the current humidity beco...

Страница 14: ...he outside air when the air temperature is low Using Child Lock You can lock the switches Use this function when you want to stop children operating the unit Press for 3 or more seconds Child Lock Indicator If you lock the unit when the POWER is OFF The unit will not turn on even if you press the POWER button to turn it on Only the CHILD LOCK lamp will blink Pressing the POWER button again will ca...

Страница 15: ...drip proof or water proof structure Water coming into contact with the unit may result in a fire due to a short circuit or an electric shock Preparation Install the dehumidifier in the dressing room Adjust the downward blowing louvre as desired P16 1 Press P12 2 Press to select BATHROOM MILDEW GUARD Changes with every press A border is displayed around the selected operating mode Start operation Ai...

Страница 16: ...re at the desired angle Stop swing The louvre stops and the swing monitor disappears Wait until the louvre stops and then adjust the angle by hand To cover the entire room Wide swing The louvre swings so that air is blown over a wide area The blowing range is approximately 135 The moving range of the louvre is approximately 120 For drying clothes etc Upward swing Swing speed is automatically contr...

Страница 17: ...returns to continuous operation Information The off timer and on timer cannot be set at the same time If you use INTELLIGENT LAUNDRY or BATHROOM MILDEW GUARD in conjunction with the off timer the operation may stop before drying is complete The off timer cannot be set while the drying inside operation is being performed ON Timer Operation You can set an operating start time between 1 to 9 hours Se...

Страница 18: ...ilation during operation Information The odor cannot be removed in the following cases When the temperature and humidity inside the room are low When there are many clothes The odor will not be removed from parts not blown by the wind The sharp odor such as perfumes and chemicals cannot be removed The odor of oil and dirt on clothes cannot be removed If the operation has little effect try the oper...

Страница 19: ... expelled from inside the unit may smell due to odorants that were not caught by the filter dissolving in the water The silver ion filter is mainly for absorbing ammonia The OFF timer cannot be set during drying inside operation Automatic operation To activate internal cleaning after every use Press while the power is ON Drying inside operation standby The DRYING INSIDE lamp lights The operation end...

Страница 20: ...sp handle and slide out If you remove the tank the FULL lamp lights Hold the tank this way 2 Remove the tank lid and pour out the water Floating element Do not remove this Tank lid Tank guard Pour the water out as shown 3 Slide the tank lid to close the tank 4 Check the tank and firmly push it all the way in Tank Make sure the tank is not broken or cracked Tank lid Tank guard Make sure it is inser...

Страница 21: ...t once a fortnight Foreign objects etc could clog the hose resulting in overheating and or leakage Note Confirm that the hose does not show signs of deterioration such as bending cracks and clogging Inspect the hose every 2 weeks Insects or dirt blocking the hose may cause leakage resulting in malfunctions Preparation Turn the POWER switch OFF and remove the power plug 1 Remove the water tank 2 Ope...

Страница 22: ...he pre filter Use a vacuum cleaner to suck up any dirt When the filter is very dirty wash it in lukewarm water and dry it well 4 Clean the sensor part Use a vacuum cleaner to suck up any dirt 5 Set the silver ion filter Make sure the silver ion filter is attached to the unit If it is not fine dust will enter inside the unit and cause a malfunction 6 Set the pre filter Once Every Three Months Silver...

Страница 23: ...lectric dealer Storage and Disposal Storage After switching the unit off leave for one day until any water inside has had time to settle Then carry out the following steps 1 Perform drying inside P19 Performing internal drying to prevent mildew growth is recommended 2 Hang the power cord on the cord hook 3 Drain out the water P20 Drain the water from the tank and wipe away any remaining drops of w...

Страница 24: ...8 Check to see if the water tank is full Empty the water tank and return it to its original position P20 Check to see if the water tank is inserted properly Adjust the position of the water tank P10 Check to see if the unit is in defrosting mode The unit activates defrosting mode when the room temperature drops below 15 C The dehumidifier and blower functions stop during defrosting P3 Is operation ...

Страница 25: ...hanges in volume The unit produces a simmering sound The unit produces a buzz that sounds intermittently or the compressor does not activate When first used The heat converter heats rapidly causing an odour This is not a malfunction The moisture expelled from inside the unit may smell due to odorants that were not caught by the silver ion filter dissolving in the water This is not a malfunction The...

Страница 26: ... of purchase Day Month Year Sole Agent in Hong Kong Mitsubishi Electric Ryoden Air Conditioning Visual Information Systems Hong Kong Limited Office Tel 2510 1505 Service Center Tel 2427 8484 Model MJ E26CX H Power supply Single phase 220 240V 50Hz Dehumidifying capacity 25 0 L day Power consumption 415W Water tank capacity stops automatically at approx 4 7L Weight 15 5kg Dimensions h w d 594mm 372m...

Отзывы: