10 - 7
10. OPTIONS AND AUXILIARY EQUIPMENT
(c) MR-H AN
NFB
MC
RA1
L
1
L
2
L
3
L
11
L
21
U
V
W
RA1
EMG
RA1
U
V
W
M
13 W
14
V
U
a
b
VDD
22
VIN
20
ALM
48
SON
12
EMG
46
SG
40
SD
50
P
N
P
N
P
N
EMG
OFF
ON
MC
MC
SK
L
11
L
21
P
N
CN1
Converter unit
Servo amplifier
Servo motor
Operation-ready
3-Phase
200 to
230VAC
50/60Hz
Power
supply
(Note)
Dynamic brake
Note. Configure up the circuit so that power is switched off in the external sequence at servo alarm occurrence.
(d) MR-H BN
NFB
MC
RA1
L
1
L
2
L
3
L
11
L
21
U
V
W
EM1
RA1
U
V
W
M
13 W
14
V
U
a
b
COM
3B
DB
4A
EM1
1A
EM2
1B
P
N
P
N
P
N
EM1
OFF
ON
MC
MC
SK
L
11
L
21
P
N
CN6
DC24V
3-Phase
200 to
230VAC
50/60Hz
Power
supply
Converter unit
Servo amplifier
Servo motor
Operation-ready
(Note1)
(Note2)
Dynamic brake
Note 1. Configure up the circuit so that power is switched off in the external sequence at servo alarm occurrence.
2. Terminals 13, 14 are N/O contact outputs. When the dynamic brake has stuck, terminals 13, 14 are opened. Therefore,
configure up the circuit to prevent servo-on in the external sequence.
Downloaded from
Содержание MELSERVO MR-HP30KA
Страница 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Страница 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Страница 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Страница 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Страница 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...