10.1 200V class dedicated options
10.1.1 Regenerative brake option (200V class)
CAUTION
The specified combinations of regenerative brake options and servo amplifiers
may only be used. Otherwise, a fire may occur.
(1) Combination and regenerative power
The regenerative power values in the table are the regenerative power of the resistor and are not the
rated power.
Regenerative Power [W]
Servo Amplifier
Converter unit
MR-RB139 (1.3 )
(Note) Three MR-RB137
(1.3 ) in parallel
MR-J2S-30KA/B MR-H30KAN/BN
MR-J2S-37KA/B MR-H37KAN/BN
MR-HP30KA
1300
3900
Note. The composite resistor value of three options is 1.3 . The resistor value of one option is 4 .
(2) Parameter setting
When using the regenerative brake option, set the parameter of the converter unit. Match parameter
No. 0 to the regenerative brake option used.
ParameterNo.0
Regenerative brake option selection
0: Not used
1: MR-RB139
2: MR-RB137(3 pcs.)
(3) Regenerative loss of servo amplifier and servo motor
Servo Amplifier
Inverse Efficiency [%]
C Charge [J]
MR-J2S-30KA/B MR-H30KAN/BN
MR-J2S-37KA/B MR-H37KAN/BN
90
390
Downloaded from
Содержание MELSERVO MR-HP30KA
Страница 11: ...A 10 MEMO Downloaded from ManualsNet com search engine ...
Страница 15: ...4 MEMO Downloaded from ManualsNet com search engine ...
Страница 63: ...5 6 5 PARAMETER MEMO Downloaded from ManualsNet com search engine ...
Страница 71: ...7 6 7 TROUBLESHOOTING MEMO Downloaded from ManualsNet com search engine ...
Страница 79: ...8 8 8 OUTLINE DIMENSIONAL DRAWINGS MEMO Downloaded from ManualsNet com search engine ...