44
2 APPENDIX
2.1 CC-Link IE TSN
• Control switching for continuous operation to torque control mode (ct)
To switch to continuous operation to the torque control mode (ct), the switching must be performed from the cyclic
synchronous position mode (csp) or cyclic synchronous velocity mode (csv). Only the "csp" and "csv" control modes switch to
"ct". To switch to "ct", set [Modes of operation (Obj. 6060h)] to "-104" while in the "csp" or "csv" control mode. Once the
condition for control switching is met, the control mode will switch to "ct", following which [Modes of operation display (Obj.
6061h)] is changed to "-104". If the condition is not met, the control mode will not be switched and the value in [Modes of
operation display] will not be changed. Continuous operation to torque control cannot be changed to "cst", "hm", etc. Refer to
the following table for details.
*1 The state where S_ZSP (Bit 3 of [Status DO 2 (Obj. 2D12h)]) is turned on. (servo motor speed being less than zero speed set in [Pr.
PC07])
Switching operation
Switching condition
(1)
Cyclic synchronous position mode
→
Cyclic synchronous torque mode
Servo motor being stopped
(2)
Cyclic synchronous position mode
→
Continuous operation to torque control mode
No condition
(3)
Cyclic synchronous torque mode, Continuous operation to torque control mode
→
Cyclic
synchronous position mode
Servo motor being stopped
(4)
Cyclic synchronous velocity mode
→
Cyclic synchronous torque mode, Continuous operation
to torque control mode
No condition
(5)
Cyclic synchronous torque mode, Continuous operation to torque control mode
→
Cyclic
synchronous velocity mode
(6)
Cyclic synchronous position mode
→
Cyclic synchronous velocity mode
Servo motor being stopped
(7)
Cyclic synchronous velocity mode
→
Cyclic synchronous position mode
Servo motor being stopped
[Modes of operation display] = 1
[Modes of operation display] = 3
[Modes of operation display] = 4
[Modes of operation display] = 8
[Modes of operation display] = -104
[Modes of operation display] = 10
[Modes of operation] = 8
[Modes of operation] = 10
[Modes of operation] = 9
(3)
(1)
(6)
[Modes of operation] = 10
(4)
[Modes of operation] = 9
(5)
[Modes of operation display] = 9
[Modes of operation] = -104
(2)
[Modes of operation] = -104
(4)
[Modes of operation] = 8 (7)
[Modes of operation] = 8
(3)
[Modes of operation] = 9
(5)
PP mode
PV mode
TQ mode
CSP mode
Continuous operation
to torque control mode
CST mode
CSV mode
The continuous operation to torque control mode cannot be changed to the profile modes.
Содержание Melservo-Jet MR-JET-G
Страница 1: ...MR JET G User s Manual Communication Function MR JET _G Mitsubishi Electric AC Servo System ...
Страница 2: ......