2 APPENDIX
2.1 CC-Link IE TSN
37
2
■
Bit definition of Status DO
With the communication function, the on/off state of the output device can be checked by reading the following objects.
• Status DO 1
• Status DO 2
Bit
Symbol
Description
Reference
0
The value at reading is undefined.
1
2
S_SA
Speed reached
Refer to "SIGNALS AND
WIRING" in the following manual.
MR-JET User's Manual
(Hardware)
3
S_MBR
Electromagnetic brake interlock
4
S_CDPS
Variable gain enabled
5
The value at reading is undefined.
6
7
8
9
10
11
12
S_INP
In-position
Refer to "SIGNALS AND
WIRING" in the following manual.
MR-JET User's Manual
(Hardware)
13
S_TLC
Limiting torque
14
S_ABSV
Absolute position undetermined
1: Absolute position is erased
15
S_BWNG
Battery warning
Bit
Symbol
Description
Reference
0
S_ZPASS
Z-phase already passed
After the Z-phase is passed, S_ZPASS turns on.
1
The value at reading is undefined.
2
3
S_ZSP
Zero speed detection
Refer to "SIGNALS AND
WIRING" in the following manual.
MR-JET User's Manual
(Hardware)
4
S_VLC
Limiting speed
5
The value at reading is undefined.
6
7
8
S_PC
Proportional control in progress
S_PC is turned on under proportional control.
9
The value at reading is undefined.
10
11
12
13
14
15
S_ZP2
Homing completion 2
When homing finishes successfully, S_ZP2 turns on.