![Mitsubishi Electric melsec q03ud(E)cpu Скачать руководство пользователя страница 200](http://html.mh-extra.com/html/mitsubishi-electric/melsec-q03ud-e-cpu/melsec-q03ud-e-cpu_user-manual_239150200.webp)
198
APPENDICES
Appendix 1
Operation Processing Time for Each
Instruction
The following table lists the processing time of instructions described in this manual.
For details on the processing time, refer to the following.
MELSEC-Q/L
Programming
Manual (Common Instruction)
Type
Instruction
Condition
Processing time(
µ
s)
QnUDVCPU
QnUDE(H)CPU
Minimum Maximum Minimum Maximum
Instructions for
the socket
communication
function
SP.SOCOPEN
TCP
Active
14.900
34.800
18.500
40.900
Unpassive
14.900
32.500
18.400
40.900
Fullpassive
14.900
32.400
18.400
40.900
UDP
14.900
34.600
18.400
40.900
SP.SOCCLOSE
TCP
From the host CPU
14.600
34.100
18.500
40.100
From the connected device
14.600
34.000
18.500
40.000
UDP
14.600
33.400
18.900
40.100
SP.SOCRCV
TCP
Minimum data volume (1 byte)
6.400
25.000
17.000
39.100
Maximum data volume (2046 bytes)
6.300
24.900
17.500
39.100
Maximum data volume (10238 bytes)
6.200
24.700
17.500
39.100
UDP
Minimum data volume (1 byte)
6.200
25.000
17.100
39.100
Maximum data volume (2046 bytes)
6.300
25.000
17.500
39.100
Maximum data volume (10238 bytes)
6.300
24.900
17.500
39.100
S.SOCRCVS
TCP
Minimum data volume (1 byte)
14.000
36.600
12.300
29.100
Maximum data volume (2046 bytes)
37.900
66.700
243.400
259.100
Maximum data volume (10238 bytes)
149.100
190.400
1168.600
1185.300
UDP
Minimum data volume (1 byte)
14.200
36.500
12.800
30.100
Maximum data volume (2046 bytes)
38.100
69.100
243.400
259.100
Maximum data volume (10238 bytes)
153.800
191.800
1167.600
1185.300
SP.SOCSND
TCP
Minimum data volume (1 byte)
11.700
34.500
18.900
43.100
Maximum data volume (2046 bytes)
41.100
75.900
290.000
313.700
Maximum data volume (10238 bytes)
177.600
235.800
1367.600
1407.300
UDP
Minimum data volume (1 byte)
11.400
35.400
18.900
43.100
Maximum data volume (2046 bytes)
41.800
76.800
290.000
313.700
Maximum data volume (10238 bytes)
189.800
235.900
1367.600
1407.300
SP.SOCCINF
-
4.900
20.800
12.700
32.200
SP.SOCCSET
-
4.200
19.200
10.700
29.200
SP.SOCRMODE
Standard mode
→
Fixed-length mode
8.500
19.400
9.700
27.200
Fixed-length mode
→
Standard mode
8.300
19.400
9.700
27.200
SP.SOCRDATA
Minimum data volume (1 word)
4.400
19.200
9.700
27.200
Maximum data volume (1024 words)
28.100
51.800
241.700
258.200
Maximum data volume (5120 words)
144.200
173.800
1168.600
1184.300
Содержание melsec q03ud(E)cpu
Страница 2: ......
Страница 11: ...9 Memo ...
Страница 209: ...207 APPENDICES A Appendix 4 Specifications Comparison with Ethernet Module Memo ...
Страница 213: ...211 Memo ...
Страница 219: ......