7.4.6
Reading out connection information (SP.SOCCINF)
(1) Setting data
*1
The "Set by" column indicates the following.
User: The data must be set before executing the SP.SOCCINF instruction.
System: The CPU module stores the execution result of the SP.SOCCINF instruction.
Setting
data
Internal device
R, ZR
J
\
U
\G
Zn
Constant
K, H
Others
Bit
Word
Bit
Word
-
-
-
-
-
-
-
-
-
-
-
Setting data
Description
Set by
*1
Data type
U0
Dummy
-
Character string
Connection number (Setting range: 1 to 16)
User
BIN 16-bit
Start number of the device from which control data are stored
System
Device name
Start number of the device from which connection information
is stored
SP.SOCCINF
SP.SOCCINF
U0
S1
S2
D
Command
S1
S2
D
S1
S2
D