3. Setting
17
3.2 Setting menu 1: Basic Settings (Setting the Phase Wire System, Display Pattern,
VT/Direct Voltage, CT Primary Current, etc.)
SET
DISPLAY
(
2
)
For other phase wire system except 3-phase 4-wire
Di
sp
lay
P
a
tt
e
rn
Cur
re
n
t
C
u
rr
e
n
t
D
e
m
a
n
d
V
o
lta
g
e
A
ctive
P
o
wer
P
ower
F
acto
r
F
re
q
u
e
n
c
y
A
ctive
E
n
e
rg
y(
Im
p
o
rte
d
)
Additional
display
A
ctive
E
n
e
rg
y
(Im
p
o
rte
d
)
Har
m
o
n
ic
Cur
re
n
t/
V
o
lt
a
g
e
Op
e
ra
ti
o
n
tim
e
P01
○
○
○
○
△
△
P02
○
○
○
○
○
○
○
△
△
P03
○
○
△
△
P04
○
○
○
△
△
P05
○
○
○
○
○
△
△
P06
○
○
○
△
△
P07
○
○
○
○
△
△
P08
○
○
○
○
○
△
△
P09
○
○
○
○
○
○
△
△
P00
□
□
□
□
□
□
□
△
△
△
Note: The following settings are required for displaying elements on an additional display.
Measurement element on additional
display
Setting item
Reference
Pages
Operation time
Setting Menu 8 Operation time display
Page 28
※
When display elements does not set active energy, ’P00’ of active energy on additional display does
not appear.
Set the VT
When direct input (without VT)
⇒
Select no, and then press , shift to following (1).
When using VT
⇒
Select yES, and then press , shift to following (2)
1.
For 3-phase 4-wire
2. For
3-phase 3-wire or 1-phase 2-wire
Note. VT is voltage transformers.
(1)
For direct input (without VT)Set the direct voltage.
(
a
)
For 3-phase 4-wire
(phase to neutral voltage / phase to phase voltage)
(
b
)
For 3-phase 3-wire (2CT, 3CT) or 1-phase 2-wire
(
c
)
For 1-phase 3-wire
(
1N2, 1N3
)
(phase to neutral voltage / phase to phase voltage)
③
VT / direct voltage
<When
①
phase wire system is set to 1-phase 3-wire>
Use only for direct input. This setting will be skipped.
SET
SET
110V
220V
440V
yES
no
110/220V
220/440V
no
yES
63.5/110V
100/173V
110/190V
220/380V
230/400V
240/415V
277/480V
254/440V
(
2
)
For other phase wire system except 3-phase 4-wire
Di
sp
lay
P
a
tt
e
rn
Cur
re
n
t
C
u
rr
e
n
t
D
e
m
a
n
d
V
o
lta
g
e
A
ctive
P
o
wer
P
ower
F
acto
r
F
re
q
u
e
n
c
y
A
ctive
E
n
e
rg
y(
Im
p
o
rte
d
)
Additional
display
A
ctive
E
n
e
rg
y
(Im
p
o
rte
d
)
Har
m
o
n
ic
Cur
re
n
t/
V
o
lt
a
g
e
Op
e
ra
ti
o
n
tim
e
P01
○
○
○
○
△
△
P02
○
○
○
○
○
○
○
△
△
P03
○
○
△
△
P04
○
○
○
△
△
P05
○
○
○
○
○
△
△
P06
○
○
○
△
△
P07
○
○
○
○
△
△
P08
○
○
○
○
○
△
△
P09
○
○
○
○
○
○
△
△
P00
□
□
□
□
□
□
□
△
△
△
Note: The following settings are required for displaying elements on an additional display.
Measurement element on additional
display
Setting item
Reference
Pages
Operation time
Setting Menu 8 Operation time display
Page 28
※
When display elements does not set active energy, ’P00’ of active energy on additional display does
not appear.