![Mitsubishi Electric MA-E85R-E Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/mitsubishi-electric/ma-e85r-e/ma-e85r-e_service-manual_237961003.webp)
3
To prevent personal injur
y, injur
y to others, or property damage, the following precautions must be obser
ved.
WARNING
Indicates a hazard caused by mishandling that may result in death or serious injur
y.
CAUTION
Indicates a hazard caused by mishandling that may result in a minor injur
y or damage to the
home and its contents.
The following categories describe hazards caused by mishandling and their levels.
Prohibited
Beware of rotating device
Do not disassemble
Do not use near water
The meanings of the graphic symbols used in this manual and on the unit are as follows.
Obser
ve
instructions
W
ARNING
Do not use a damaged power cord and plug, or a loose power outlet.
This may cause
electric shock, short circuit, or
fire
.
Do not damage the power cord and plug.
Do not unnecessarily bend, pull, twist, or bind the power cord, place it close to a hot object, place a heavy object on it, trap it between objects, or modify it.
•
If the power cord is damaged, it must be replaced by the manufacturer
, its ser
vice agents, or a similarly
qualified person to avoid hazards.
This may cause damage, resulting in
fire or electric
shock
.
(Also take care that a pet does not bite the power cord.)
Do not repair
, disassemble,
or modify the unit.
This may cause
fire or electric shock
.
For repairs, contact the retail store where you purchased the product.
Do not put a wire, pole, or other foreign object or a finger into an air inlet or outlet or any other opening into the unit.
This may cause
electric shock or
injur
y
.
Use a 220-240 V AC power outlet.
Using other than a 220-240 V AC power outlet may cause
electric shock, short circuit, or fire
.
Remove the power plug before cleaning. Also, do not remove the power plug with a wet hand.
This may cause
electric shock or injur
y
.
Remove dust from the power plug regularly
.
If dust accumulates, humidity
, etc. may cause an
insulation failure, resulting in
fire
.
If the unit is operating abnormally or fails, stop using it immediately
.
•
The unit does not operate when the operation On/ Off switch is turned ON.
•
The unit, power cord, or plug is abnormally hot.
•
There is an abnormal noise or vibration during operation.
•
There is a burning smell.
•
The operating sound is abnormally loud.
•
Mounting screws are corroded or loose.
•
The earth leakage circuit breaker trips frequently
.
•
There is another abnormality or failure.
Failure to do so may cause
fire, electric shock, or
injur
y
.
Immediately turn OFF the operation On/Off switch and disconnect the power plug, and then contact the retail store.
Do not allow flammable gas to be sucked inside or use the unit where flammable gas accumulates.
(Factor
y, beauty salon, etc.)
This may cause
fire
.
Do not place the unit close to flammable objects or objects lit with fire, such as cigarettes or incense sticks.
This may cause
fire
.
Do not get on top of or lean against the unit.
This may cause the unit to topple or fall and cause
injur
y
.
Do not lay the unit horizontally when removing a filter
.
This may cause dust to enter inside, resulting in
fire
or electric shock
.
Do not use a damaged filter or operate the unit while a filter is removed.
This may cause dust to enter inside, resulting in
fire
or electric shock
.
Do not install the unit where water may be spilt onto it or where there is a lot of humidity such as in a bathroom.
This may cause
electric shock
.
Should water or other liquid be spilt onto the unit, stop operation and remove the power plug, and then contact the retail store where you purchased the product.
Do not use the unit in a location with the oily smoke of machine oil or other oil.
This may cause cracking, resulting in
electric shock
.
Do not wipe the unit with benzene or thinner or spray insecticide or other chemicals onto it.
This may cause
electric shock, fire, or cracking
and cause injur
y
.
Do not operate the unit when using an insecticide that produces smoke.
An accumulation of chemical components may be released from the air outlet and be
harmful to your health
.
After using an insecticide, ventilate the area sufficiently prior to operating the unit.
When using the unit in combination with a combustion appliance, ventilate the room occasionally
.
Carbon monoxide cannot be removed from the air
,
so not ventilating the room may cause
carbon
monoxide poisoning
.
When disconnecting the power plug, pull it out straight while holding not the cord but the power plug.
Failure to do so may cause
electric shock or a
short circuit resulting in fire
.
When the unit will not be used for a long time, disconnect the power plug.
Failure to do so may cause the insulation to deteriorate, resulting in
fire from a short circuit or an electric
shock
.
This air purifier is designed for household use. Do not use it for commercial use.
Do not block the air inlets or outlet.
Do not use this unit instead of an exhaust fan or exhaust hood (there is no ventilation function).
Do not insert a finger or foreign object into the PM2.5 Sensor
.
Do not use the unit while it is laid horizontally
.
Do not use the unit while the inlet panel, pre-filter unit, HEP
A filter
, activated
charcoal filter
, or platinum
catalyst is removed.
This may cause
a
malfunction
.
This may cause the filter life to become shorter and cause
deformation, discoloration, or malfunction
.
This may cause
a
malfunction
.
This may cause
a
malfunction
.
This may cause
a malfunction
.
Safety Precautions
Attentions
CAUTION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensor
y
or mental capabilities or lack of experience and knowledge if they have been given super
vision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without super
vision.
Note:
This page is extracted from the full version instruction manual.
1.
Safety Precautions