10
7. Control Outline
(1) Function Operation List
Operation status
Operation
OFF
Automatic operation
Manual operation
Auto
Cleaning
Normal
Night
Turbo
Silent
Low
Mid
High
Turbo
Controlled
devices
Blower fan
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
Cleaning rotor
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Louver
CLOSE
OPEN (operation depends on the smart search mode)
LEDs
Operation mode
OFF
ON for the selected operation mode
Smart search
OFF
ON when the smart search is ON (OFF when the smart search is OFF)
Auto cleaning
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Odor monitor
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
PM2.5 monitor
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
Dust monitor
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
HEPA filter replacement
OFF
ON when the accumulated time for HEPA filter replacement is reached
Dust box cleaning
OFF
ON when the accumulated time for dust box cleaning is reached
Switches
On/Off
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Manual
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Auto
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Smart Search
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Auto Cleaning
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Reset
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
<Lamp Indication>
(1) Operation mode lamps (Silent, Low, Mid,
High, Turbo / Normal, Night, Turbo)
• Operation mode is indicated.
• One lamp is lit during operation.
• The “Normal” lamp is lit by default (automatic
operation).
(2) “Clean Dust Box” lamp
• The lamp is lit when the operation time reaches the
set value (approx. 120 days for “Silent” operation
and approx. 60 days for “Turbo” operation).
(3) “Replace Filter” lamp
• The lamp is lit when the operation time reaches the
set value (approx. 8 years for “Silent” operation and
approx. 1.6 years for “Turbo” operation).
(4) Triple clean monitors (green/yellow/orange)
• The lamp is lit in accordance with the state of odor,
PM2.5, and dust contamination.
• One green lamp is always lit.
(5) “Smart Search” lamp
• The lamp is lit when the smart search is set to ON.
(6) “Auto Cleaning” lamp
•
The lamp is lit during pre-filter cleaning.
(2) Fan Control
Rank for Rotation Speed
1
The fan rotation speed for each fan rank is controlled as follows.
2
EEPROM holds the rotation speed data and pulse initial value.
Fan rank
1
2
3
4
5
6
7
Rotation speed (rpm)
330
360
415
515
580
693
1040
Air volume (m
3
/h)
102
120
150
204
252
306
510