Sensors
(Odor sensor and PM2.5 Sensor)
Lens of PM2.5 Sensor
Dust box
Platinum catalyst and activated charcoal filter
Approximately Once a Month
1
Remove the inlet panel.
P.
8
2
Suck up the dust with a vacuum cleaner using a nozzle.
Odor sensor
PM2.5 Sensor
Located on the right side of the main unit.
3
Attach the inlet panel to the main unit.
P.
8
Cleaning (Cont.)
When the Clean Dust Box Lamp Lights Up or Approximately Once Ever
y Four
Months
1
Remove the inlet panel.
P.
8
2
Pull out the dust box and then empty it.
Dust box
3
Attach the dust box.
Push the left and right of the
dust box.
If it is not attached properly
, the removal of dust will become
difficult.
4
Attach the inlet panel to the main unit.
P.
8
5
Insert the power plug and then reset the Clean Dust Box lamp.
Press until you hear the “blip” sound (approx. 1 second).
z
The Clean Dust Box lamp goes out. (The lamp is reset.)
When you hear the “blip” sound, remove your finger from the Reset button. If you keep the button pressed, you will hear a “blip blip” sound and the filter replacement timing will also be reset.
P.16
NOTE
Approximately Once Ever
y Six Months
1
Remove the cover of the PM2.5 Sensor
.
Slide the cover to remove it.
2
Clean the lens with a dr
y cotton swab.
Do not use water
, alcohol, detergent, etc.
This may cause a malfunction.
3
Attach the cover of the PM2.5 Sensor
.
When There is an Odor Coming Out of the Air Outlet
1
Remove the inlet panel, pre-filter unit, and HEP
A filter
.
P.
8
2
Remove the activate charcoal filter
.
P.
8
3
Remove the platinum catalyst.
Hook your fingers around the handles at the bottom of the platinum catalyst and then pull the catalyst out toward you to remove it.
4
Soak and wash the platinum catalyst and activated charcoal filter
.
z
Platinum catalyst
Soak in cold or lukewarm water for approximately one hour and then wash in water
.
z
Activated charcoal filter
Soak in cold or lukewarm water for approximately one hour and then wash in water
.
Do not use detergent. Also, do not scrub it. This may cause the platinum catalyst and activated charcoal filter to become damaged.
5
Allow the platinum catalyst and activated charcoal filter to dr
y.
Allow them to dr
y properly in a well-ventilated place in the
shade for approximately six hours (the dr
ying time differs
depending on the season and climate).
z
Do not use them while they are still wet. W
ater drops may be blown from the air outlet and an odor
may be created.
z
Soaking and washing will not completely restore the deodorizing performance of the activated charcoal filter
.
Replace this filter when the time for replacement is reached.
6
Attach the platinum catalyst to the main unit.
Hook the top of the platinum catalyst and then push in the bottom.
7
Attach the activated charcoal filter to the main unit.
P.
8
8
Attach the HEP
A filter
, pre-filter unit,
and inlet panel to the main unit.
P.
8
Note: