7
8
The New Remote Controller PZ-60DR-E enable simple control setting
Can Be Used With AG-150A Centralized Controller
Centralized Controller System
LOSSNAY independent
Interlocked with Air conditioners
Interlocked with City Multi
Interlocked with Mr.Slim
City Multi
M-NET transmission line
Mr.Slim
LOSSNAY
RX
5
LOSSNAY
RX
5
Slim-LOSSNAY connection cable
LOSSNAY remote
controller
PZ-60DR-E
LOSSNAY remote
controller
PZ-60DR-E
can be connected
LOSSNAY RX
5
(Max 15 unit)
PZ-52SF-E can be used insted of PZ-60DR-E,
However, function is limited and connecting
position is different.
The LOSSNAY remote controller (PZ-60DR-E,
PZ-41SLB-E) can not be used with this system.
PZ-41SLB-E can be connected however function
is limited.
Centralized controller
AG-150A
Power supply unit
(PAC-SC51KUA)
Outdoor unit
Network remote
controller
Mr.Slim
remote controller
LOSSNAY remote
controller
PZ-60DR-E
LOSSNAY remote
controller
PZ-60DR-E
Mr.Slim
outdoor unit
Mr.Slim
indoor unit
Network remote
controller
LOSSNAY
RX
5
LOSSNAY
RX
5
LOSSNAY
RX
5
LOSSNAY
RX
5
LOSSNAY remote
controller
PZ-60DR-E
LOSSNAY
RX
5
Ext. signal source
LOSSNAY remote
controller
PZ-60DR-E
Interlocked with
City Multi indoor units
Interlocked with
Mr. Slim indoor units
LOSSNAY units only
Interlocked with
external devices
Internet
Switching Hub
Hub
LAN
(100BASE-TX)
A Control
Central Control PC
(TG-2000A)
*Ver. 5.50 or later
Remote
Monitoring PC
Hub
DIDO Controller (PAC-YG66DCA)
General Equipment
Temp/Humidity sensor
Watt hour meter
AI Controller (PAC-YG63MCA)
PI Controller (PAC-YG60MCA)
Note : Use a security device such as a VPN router when connecting the
AG-150A to the Internet to prevent unauthorized access.
AG-150A / GB-50A
M-NET
M-NET
Service company
/Sales office
Mobile phone
of service person
Remote
monitoring PC
M-NET
M-NET
adapter
AG -150A
Remote monitoring
via a Web browser
Remote monitoring
via a Web browser
VPN
Router
VPN
Router
Modem
Power supply unit
(PAC-SC51KUA)
Lights
Ventilation
Modem
Functions
Item
Controllable unit
ON/OFF
Operation mode switching
Temperature setting
Fan speed setting
Air flow direction setting
Schedule operation
Permit / Prohibit
local operation
Indoor unit intake temperature
Error
Test run
Ventilation interlock
External input/output
Description
Up to 50 units/groups.
Run and stop operation for the air conditioner units and general equipment.
(To operate general equipment, PAC-YG66DCA is required.)
Switches between Cool / Dry / Auto / Fan / Heat. (Group of LOSSNAY unit : automatic ventilation/
vent - heat interchange/ normal ventilation) depending on the air conditioner unit.
Auto mode is for City Multi R2 and WR2 series only.
Cool/Dry : 19 (67 ) - 30 (87 ) [14 (57 ) - 30 (87 )]
Heat : 17 (63 ) - 28 (83 ) [17 (63 ) - 28 (83 )]
Auto : 19 (67 ) - 28 (83 ) [17 (63 ) - 28 (83 )]
[ ] in case of using middle-temperature on PDFY, PEFY-VML/VMR/VMS/VMH-by setting DipSW7-1 to ON.
Yet, PEFY-P-VMH-E-F is excluded.
Models with 4 air flow speed settings: Hi/Mid-2/Mid-1/Low
Models with 3 air flow speed settings: Hi/Mid/Low
Models with 2 air flow speed settings: Hi/Low
Fan speed setting (including Auto) varies depending on the model.
Air flow direction angles, 4-angle or 5-angle Swing, Auto (Louver cannot be set)
Weekly schedule can be set by groups based on daily operation pattern.
Individually prohibit operation of each local remote control function
(Start/Stop, Change operation mode, Set temperature, Reset filter).
Measures the intake temperature of the indoor unit only when the indoor unit is operating.
When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed.
This operates air conditioner units in test run mode.
The ventilation unit (LOSSNAY) is able to automatically start its operation when operation of the interlocked indoor unit starts.
By using optional external input/output adaptor (PAC-YG10HA) you can set and monitor the following.
Input : By level signal : "Batch start/stop", "Batch emergency stop"
By pulse signal : "Batch start/stop", "Enable/disable local remote controller"
Output : "Start/stop", "Error/Normal"
Operations
Display
X
X
*NOTE: Operation and displayed content vary depending on the indoor unit model.
: Each block
System structure
Controllers are one of the most important and familiar devices in an air conditioning system. Not only does it control to provide
optimum air environment but supports operations to minimize running costs and to preserve energy. Through studies and
development, we've visualized a new system controller meeting needs with versatile options.
With a new coloured touch panel, new functions, and continuation of all the current G-50A functions, AG-150A visualizes its
functions from basic control to advanced operations and bringing an ultimate controller to reality.
– Design your control
with our new centralized controller; AG -150A.
Indoor unit
Indoor unit
: Each floor
: Each unit
: Collective
: Each group
: Not available
Control