24
─
(12) Blower assembly (assy)
1
Remove the blower cover.
→
See (8)
1
to
2
, (11)
1
(Remove the side panel R clamping screw only), and
4
to
5
.
Precaution
Since the blower (assy) may drop off the blower case, remove the lead wires first, and then slowly remove
the blower cover.
Blower (assy)
Set the blower horizontally.
2
Remove the blower (assy).
(13) Sensor circuit board (Lower sensor) (JT-30S3R)
1
Remove the blower (assy).
→
See (7)
1
and (12).
2
Unscrew the clamping screws, and remove the blower case.
(Three PTT screws 4×16, indicated by
)
Blower case
3
Unscrew the panel (front) and panel holder clamping screws, and
remove the panel holders L and R.
(Five PTT screws 4×16, indicated by
)
Panel (front)
Panel holder L
Panel holder R
Assembly precautions
• When replacing the blower (assy), attach the included fixing piece to the position, indicated by
, with
the included screw (one PTT screw 4×16).
• Set the blower (assy) as the lead wire outlet comes to the position indicated by
.
• The part of the lead wires covered with the white cord tube must pass through the cord bush. (Indicated
by
)
Fixing piece
Align the cord bush
with the marking.