1 - 14 1 - 14
MELSEC-Q
1 OVERVIEW
Function Outline
of
function
Supported module
Supported protocol
Reference
section
QJ71C24N
(-R2/R4)
QJ71C24
(-R2)
MC
Non
procedure
Bi-
directional
Pre-
defined
Remote password
check
This function allows data communication after
the external device completes the unlock
processing of the remote password set at a
QCPU. It is executed when the QCPU is
accessed from a remote location using the
modem function of the Q series C24 in the
following forms of data communication:
• Communication using the MC protocol
• Communication using GX Developer
User's
Manual
(Application)
Reference
Manual
Addition of non
reception monitoring
time format in non
procedure protocol
This function allows messages to be received
in the non reception protocol by time-out in
non reception monitoring time (timer 0) if the
received complete code and received data
count have been not determined.
User's
Manual
(Application)
Transmission control
start/end free area
designation
This function allows the designation of the
available capacity of the OS area that notifies
the data reception failure at the time of
transmission control (DTR/DSR signal control
and DC code control).
User's
Manual
(Application)
Addition of changeable
data to the user frame
(05
H
, 0B
H
, 11
H
, 17
H
)
These functions allow the following codes to
be registered as the changeable data of user
frames for data communication.
• Horizontal parity code
• Sum check code of two's-complement
number
User's
Manual
(Application)
Addition of changeable
data to the user frame
(04
H
, 0A
H,
E5
H,
EB
H
)
Adding a reception
function through the
use of user frames
This function allows reception of a message
consisting of the head frame and any data
field when receiving data by specifying the
head frame.
The data length of the data field can be
specified freely for each combination of user
frames for reception set by the user.
(Receiving 1 byte providing ACK/NAK only is
also possible by setting the data length of the
data field to “0.”)
User's
Manual
(Application)
Multiple specification of
transparent codes for
transmission
This function allows specification of a
maximum of 10 types of transparent codes for
transmission per interface when sending data
using one of the following protocols:
• Non procedure protocol
• Bidirectional protocol
User's
Manual
(Application)
Switching to the GX
Developer connection
mode by switching the
mode
This function allows the GX Developer
connection mode to be switched by an
external device or the programmable
controller CPU.
User's
Manual
(Application)
Reference
Manual
Communication data
monitoring function
This function allows the monitoring of
communication data transmitted on the
communication network of the Q series C24
and an external device.
User's
Manual
(Application)
Operating
Manual
(Protocol FB
support
function)
UINI instruction
The UINI instruction allows change of the
mode, transmission specifications and host
station No. of the Q series C24.
User's
Manual
(Application)
Specification of station
No.65 to 120 by MC
protocol
(QnA compatible 4C/3C
frame only)
This function allows to access station No. 65
to 120 of CC-Link IE Controller Network and
CC-Link IE Field Network.
Reference
Manual
Содержание GX Configurator-SC
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 138: ...4 35 4 35 MELSEC Q 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDICES Connection example 3 Connection example 4 ...
Страница 439: ...WARRANTY ...
Страница 441: ......