Appendix 9.7 When sending data using user frames
The following program example sends data by the user frames using the
REMFR/REMTO instruction and I/O signals.
Refer to the User's Manual (Application) for the transmission using the user frames.
(1) Program
conditions
The following program sends data using the user frames from the CH1 side when
the transmission signal (X1026) turns ON.
(a) Devices
used
:
• Transmission command ........................................................ X1026
• Transmission command pulse signal ................................... M10
• Transmission user frame designation command ................. M11
• Transmission result acquisition command ........................... M12
• Completion device for REMFR/REMTO instruction ............. M100 to 105
• Normal/abnormal completion flag for REMFR/REMTO
instruction .............................................................................. M200 to 203
• Normal/abnormal completion of transmission ...................... M300, M301
• Transmission data count ....................................................... D0
• Transmission data ................................................................. D1, D2
• CR/LF output designation ..................................................... D5
• Output head pointer designation........................................... D6
• Output count designation ...................................................... D7
• Output frame No. designation ............................................... D8 to D12
• Data transmission result ........................................................ D20
(b) Intelligent function module switch settings (Refer to Section 4.5.2.)
Switch No.
Bit
Description
Setting
value
Position Designated
value
Switch 1
b0 OFF
Transmission
setting
Operation setting
Independent
07C2
H
b1 ON
Data
bit
8
bits
b2 OFF
Parity
bit
No
b3 OFF
Even/odd
parity
Odd
b4
OFF
Stop bit
1 bit
b5
OFF
Sum check code
No
b6 ON
Write
during
RUN Enabled
b7 ON
Setting
modifications
Enabled
b8 to b15
—
Communication rate setting
19200bps
Switch 2
—
Communication protocol setting
Non-procedure protocol
0006
H
Switch 5
—
Station number setting
Station 0
0000
H
Содержание GX Configurator-SC
Страница 2: ......
Страница 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Страница 138: ...4 35 4 35 MELSEC Q 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION MEMO ...
Страница 397: ...App 24 App 24 MELSEC Q APPENDICES Connection example 3 Connection example 4 ...
Страница 439: ...WARRANTY ...
Страница 441: ......