5.1 Overview
5 - 1
5
EMC DIR
ECTIVE
5. EMC DIRECTIVE
5.1
Overview
For the products sold in European countries, the conformance to the EMC Directive, which is one of the European
Directives, has been a legal obligation since 1996.
Manufacturers, who recognize that their products comply with the EMC Directive must declare that their products comply
with the Directives and put a CE mark on the products.
■1.
Sales representative in Europe
The sales representative in Europe is as shown below.
Company name: Mitsubishi Electric Europe BV
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
5.1.1
Conforming standards in the EMC Directive
The GOT complies with the following standards in the EMC Directive.
*1
The GOT is an open type device (designed to be integrated in equipment).
Make sure to install the GOT on a control panel.
This test item is conducted in the condition where the GOT is installed on a control panel and combined with the MITSUBISHI
PLC.
*2
QP: Quasi-peak value, Mean: Average value
*3
This test item is conducted in the following conditions.
• 30 MHz to 230 MHz
QP: 40 dBμV/m (measured at 10 m)
• 230MHz to 1000MHz
QP: 47 dBμV/m (measured at 10 m)
Applied
standard
Test standard
Test details
Standard value
EN61131-2
: 2007
CISPR16-2-3
Radiated noise
*1
Test for measuring electromagnetic
emissions from the product
• 30 MHz to 230 MHz
QP: 30 dBμV/m (measured at 30 m)
*2*3
• 230 MHz to 1000 MHz
QP: 37 dBμV/m (measured at 30 m)
*2*3
IEC61000-4-2
Electrostatic immunity
*1
Immunity test in which static electricity
is applied to the cabinet of the
equipment
• Contact discharge: ±4 kV
• Aerial discharge: ±8 kV
IEC61000-4-3
Radiated electromagnetic
field, amplitude modulation
*1
Immunity test in which an electric field
is applied to the product
80 MHz to 1000 MHz: 10 V/m
1.4 GHz to 2 GHz: 3 V/m
2.0 GHz to 2.7 GHz: 1 V/m
(80% amplitude modulation at 1 kHz)
IEC61000-4-4
Fast transient burst noise
*1
Immunity test in which burst noise is
applied to the power cables and the
signal lines
Power cable: 1 kV
Digital I/O: 1 kV
Analog I/O: 1 kV
Signal cable: 1 kV
IEC61000-4-5
Surge immunity
*1
Immunity test in which lightening surge
is applied to the product
• AC power type
Power cable (between cable and ground): ±2
kV
Power cable (between cables): ±1 kV
Data communication port: ±1 kV
• DC power type
Power cable (between cable and ground):
±0.5 kV
Power cable (between cables): ±0.5 kV
Data communication port: ±1 kV
IEC61000-4-6
Conducted RF immunity
*1
Immunity test in which a noise
inducted on the power cable and the
signal lines is applied
Power cable: 10 V
Data communication port: 10 V
IEC61000-4-8
Power supply frequency
magnetic field immunity
Test for checking normal operations
under the circumstance exposed to the
ferromagnetic field noise of the power
supply frequency (50/60 Hz)
30 A/m
Содержание GOT SIMPLE GS2107-WTBD
Страница 1: ...GRAPHIC OPERATION TERMINAL User s Manual GOT SIMPLE Series ...
Страница 2: ......
Страница 22: ...1 4 1 1 Features ...
Страница 26: ...2 4 2 2 Component List ...
Страница 34: ...4 4 4 3 Bottom ...
Страница 42: ...5 8 5 2 EMC Directive Requirements ...
Страница 48: ...6 6 6 5 Installation Procedure ...
Страница 56: ...7 8 7 2 Wiring Inside and Outside the Panel ...
Страница 68: ...9 10 9 3 Utility Display ...
Страница 96: ...11 26 11 7 Keyword Step 5 Touch the Execute key Step 6 The keyword is deleted Touch OK Touch Touch ...
Страница 98: ...11 28 11 7 Keyword Step 5 Touch the Execute key Step 6 The protection is cleared Touch OK Touch Touch ...
Страница 100: ...11 30 11 7 Keyword ...
Страница 116: ...12 16 12 4 GOT internal device monitor ...
Страница 134: ...13 18 13 3 Login Logout ...
Страница 146: ...14 12 14 1 Time Setting and Display ...
Страница 260: ...17 6 17 3 Clean ...
Страница 266: ...20 2 ...
Страница 282: ...23 2 ...
Страница 288: ...REVISIONS 2 ...
Страница 291: ......