15 - 46
15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
Ex
pan
si
on
par
ame
te
rs
1
49
*DO1 Output signal selection 1
Used to select the connector pins to output the alarm code and
warning (WNG).
Setting of alarm code output
Connector pins
Set value
CN1-10
CN1-11
CN1-12
0
SA
RD
ZP
1
88888
AL.12
AL.13
AL.15
AL.17
AL.8A
AL.8E
AL.30
AL.45
AL.50
AL.51
AL.24
AL.32
AL.31
AL.16
AL.20
Name
Watchdog
Memory error 1
Clock error
Memory error 2
Board error 2
Serial communication time-out error
Serial communication error
Regenerative error
Main circuit device overheat
Overload 1
Overload 2
Main circuit
Overcurrent
Overspeed
Encoder error 1
Encoder error 2
Alarm
display
(Note) Alarm code
CN1
pin 10
0
0
0
0
1
CN1
pin 11
0
0
1
1
0
1
CN1
pin 12
1
1
0
1
0
1
0
Set value
Connector pin No.
Note: 0:off
1:on
Setting of warning (WNG) output
Select the connector pin to output warning. The old signal
before selection will be unavailable.
AL.19 Memory error 3
AL.37 Parameter error
AL.33 Overvoltage
AL.46 Servo motor overheat
AL.10 Undervoltage
1
0
0
AL.1A Motor combination error
0
Not output.
1
CN1-11
2
CN1-9
3
CN1-10
4
CN1-12
0
Alarm code is output at alarm occurrence.
0
0000
Refer to
Name
and
function
column.
S T
Содержание GENERAL PURPOSE AC SERVO MR-E- A/AG
Страница 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Страница 11: ...A 10 MEMO ...
Страница 17: ...6 MEMO ...
Страница 31: ...2 4 2 INSTALLATION MEMO ...
Страница 85: ...4 6 4 OPERATION MEMO ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Страница 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...