3 - 17
3. SIGNALS AND WIRING
Control
mode
Signal
Symbol
Connec-
tor pin
No.
Functions/Applications
I/O
division
P
S
To use this signal, set " 1" in parameter No.49.
This signal is output when an alarm occurs. When there is no
alarm, respective ordinary signals (RD, INP, SA, ZSP) are output.
Alarm codes and alarm names are listed below:
(Note) Alarm code
CN1
12 Pin
CN1
11 Pin
CN1
10 Pin
Alarm
display
Name
88888
Watchdog
AL.12
Memory error 1
AL.13
Clock error
AL.15
Memory error 2
AL.17
Board error
AL.19
Memory error 3
AL.37
Parameter error
AL.8A
Serial communication
timeout
0
0
0
AL.8E Serial communication error
AL.30
Regenerative error
0
1
0
AL.33
Overvoltage
0
0
1
AL.10
Undervoltage
AL.45
Main circuit device
AL.46
Servo motor overheat
AL.50
Overload 1
0
1
1
AL.51
Overload 2
AL.24
Main circuit error
1
0
0
AL.32
Overcurrent
AL.31
Overspeed
AL.35
Command pulse frequency
alarm
1
1
0
AL.52
Error excessive
AL.16
Encoder error 1
1
0
1
AL.1A Monitor combination error
AL.20
Encoder error 2
Alarm code
ACD 0
ACD 1
ACD 2
Note.0: Pin-SG off (open)
1: Pin-SG on (short)
DO-1
Содержание GENERAL PURPOSE AC SERVO MR-E- A/AG
Страница 1: ...General Purpose AC Servo MODEL MR E A AG INSTRUCTION MANUAL B ...
Страница 11: ...A 10 MEMO ...
Страница 17: ...6 MEMO ...
Страница 31: ...2 4 2 INSTALLATION MEMO ...
Страница 85: ...4 6 4 OPERATION MEMO ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO ...
Страница 307: ...15 62 15 MR E AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT MEMO ...