8 CANopen
®
417 Mode
8.3 Virtual Input/Output Mapping
158
FX
3U
-CAN User's Manual
4. Floor field [High byte in BFM #3002 and #13002]
5. Door field [Low byte in BFM #3003 and #13003]
This value provides the door number to which the output is assigned. The structure of the field depends on
the value of the basic function field. If the bits of the door field are set to 1, this shall indicate an assignment of
the output to this door.
6. Function data field [High byte in BFM #3003 and #13003]
The function data provides the input state of a virtual input.
Value definition of the property parameter field (Bit 12 to 14)
BFM #3002
BFM #13002
High Byte Value (hex)
Description
00
Car panel
01 to FE
Floor number 1 to 254
FF
All floor panels
Basic Function Field
Door Field
Description
BFM #3001
BFM #13001
Low Byte Value (hex)
BFM #3003
BFM #13003
Low Byte Bit No.
00 to 07
or
0E to FF
Bit 0
Door 1
Bit 1
Door 2
Bit 2
Door 3
Bit 3
Door 4
Bit 4 to 7
Bit 4 to 7 fixed to OFF (0).
08 to 0D
Bit 0
Source door 1
Bit 1
Source door 2
Bit 2
Source door 3
Bit 3
Source door 4
Bit 4
Destination door 1
Bit 5
Destination door 2
Bit 6
Destination door 3
Bit 7
Destination door 4
BFM #3003
BFM #13003
(High Byte) Bit No.
Description
Bit 8
Status
OFF (0): No data indicated
(Does not apply for basic function H40)
ON (1):
Data indicated
Bit 9 to 11
Property
Bit 9 to 11 value (hex)
H0: No action (default)
H1: Output continuously
H2: Output pulsed
H3: Output flashing
H4: Output coloured
H5: Output with volume
H6: Output with scroll rate
H7: Reserved
Bit 12 to 14
Property parameter
Refer to table below
Bit 15
Predicate
OFF (0): Acknowledgement is not affirmed
ON (1):
Acknowledgement is affirmed
Bit 12 to 14
value (hex)
Description
No action
Continuous
Pulsed
Flashing
Colour
Volume
Scroll rate
0
No action
Reserved
< 0.5 s
10 Hz
White
Minimum
Automatic
1
1 s
7.5 Hz
Yellow
Vary
1 line/s
2
1.5 s
5 Hz
Reserved
Vary
2 line/s
3
2 s
2 Hz
Green
Vary
3 line/s
4
3 s
1. 5Hz
Reserved
Vary
4 line/s
5
5 s
1 Hz
Red
Vary
5 line/s
6
10 s
0.5 Hz
Reserved
Vary
6 line/s
7
> 15 s
0.25 Hz
Blue
Maximum
7 line/s