8 CANopen
®
417 Mode
8.1 Buffer Memories Lists of Lift Application
141
FX
3U
-CAN User's Manual
1
Introduc
tion
2
Specifi
cations
3
Inst
allati
on
4
Wi
rin
g
5
Introduc
tion of
Functions
6
All
ocation of
B
uff
er
Memor
ies
7
Interface and
D
evice P
rofile
(40
5 mode)
8
Lift Appl
icati
on
P
ro
file
(417 M
ode)
9
CAN
Layer 2
Mode
10
Comm
and
Interface
8. CANopen
®
417 Mode
This chapter describes the data transfer locations of the CANopen
®
417 Mode.
For further information on application Profile CiA
®
417 V2.1 for lift control systems, refer to the following
section.
→
Refer to Section 5.10
Note
• The BFM data exchange will only be handled if the corresponding lift number bit in BFM #3000/13000 is
set to ON.
→
Refer to Subsection 5.10.1 and BFM #3000/13000 in the following table.
• To ensure that the FX
3U
-CAN module can handle the CANopen
®
data in a consistent way, it is necessary
to set BFM #20 bit 0, 8 or 9 (only Virtual input mapping) to ON before reading PDO data (FROM) and after
writing PDO data (TO) to the module.
The data exchange control signal ensures, by internal buffer exchange, that TO data from the PLC will be
transmitted with its corresponding PDO at the same time.
→
For BFM #20 bit 0, refer to Section 6.4
• To activate the CiA
®
417 Lift Application Profile mode, write into BFM #21 the value K417, set BFM #22 to
K1 to store the BFM configuration and reset the Module.
• Only BFMs corresponding to the Lift Numbers for which the module is activated will be received and
transferred.
→
For the Lift number, refer to Subsection 5.10.1 and BFM #3000/13000 in the following table
8.1
Buffer Memories Lists of Lift Application
This section explains data transfer locations for CANopen
®
417 Mode. BFM #3000 to #3539, BFM #13000 to
13539 and BFM #12001 to 12539 are used as data transfer locations.
• General Setting
• Call controller
The call controller receives all call requests from the input panels, and transmits the corresponding
acknowledgements to the output panels.
- Receive Objects
BFM No. and access type
Lift No.
Description
Initial value
Reference
FROM/TO
BFM #3000
BFM #13000
1 to 8
Lift Number
H1
Section 8.2
BFM No. and access type
Lift No.
Description
Initial value
Reference
FROM
FROM
BFM #3001
BFM #12001
1 to 8
Virtual input mapping
H0
Section 8.3
BFM #3002
BFM #12002
BFM #3003
BFM #12003
BFM #3004
BFM #12004
1 to 8
Virtual input mapping message counter
H0
-
BFM #3005
BFM #12005
Reserved
-
-
..…
..…
BFM #3049
BFM #12049
Содержание FX3U-CAN