5 Introduction of Functions
5.10 Application Profile CiA
®
417 V2.1 for Lift Control Systems
97
FX
3U
-CAN User's Manual
1
Introduc
tion
2
Specifi
cations
3
Inst
allati
on
4
Wi
rin
g
5
Introduc
tion of
Functions
6
All
ocation of
B
uff
er
Memor
ies
7
Interface and
D
evice P
rofile
(40
5 mode)
8
Lift Appl
icati
on
P
ro
file
(417 M
ode)
9
CAN
Layer 2
Mode
10
Comm
and
Interface
5.10.3 Virtual output mapping
This Object contains the output data for one of the digital output group objects.
1. Basic function field
2. Sub-function field
The Sub-function field is interpreted differently depending on the basic function field value.
Bit 0 to 7
Value (hex)
Description
Bit 0 to 7
Value (hex)
Description
00
Call controller commands
11
Area monitoring connection acknowledgement
01
Generic output
12 to 1F
Reserved
02
Standard hall call acknowledgement
20
Guest call acknowledgement
03
Low priority hall call acknowledgement
21 to 3F
Reserved
04
High priority hall call acknowledgement
40
Position indication
05
Standard car call acknowledgement
41
Hall lantern
06
Low priority car call acknowledgement
42
Direction indication
07
High priority car call acknowledgement
43
Special indication
08
Standard destination call acknowledgement
44
Arrival indication
09
Low priority destination call acknowledgement
45
Operation data
0A
High priority destination call acknowledgement
46
Publicity indication
0B
Standard call to destination floor acknowledgement
47
Speech synthesis
0C
Low priority call to destination floor acknowledgement
48 to 49
Reserved
0D
High priority call to destination floor acknowledgement
4A
Miscellaneous outputs
0E
Special function acknowledgement
4B to 7F
Reserved
0F
Access code upload acknowledgement
80 to FF
Manufacturer-specific
10
Speech connection acknowledgement
Basic function field
Bit 0 to 7 value
(hex)
Sub-function field
Bit 8 to 15 value
(hex)
Description
00
00
Reserved
01
Request all active hall calls
02
Request all special inputs (basic functions 0E and 12)
03 to FF
Reserved
01
00 to FF
Reserved
02 to 04
00
Reserved
01
Hall call up acknowledgement
02
Hall call down acknowledgement
03
Hall call acknowledgement
04
Hall call extra up acknowledgement
05
Hall call extra down acknowledgement
06
Hall call extra acknowledgement
07 to FF
Reserved
05 to 0D
00
Reserved
01 to FE
Target stop acknowledgement 1 to 254
FF
All target stop buttons
0E
00
Reserved
01
Request fan 1 acknowledgement
02
Request fan 2 acknowledgement
03
Request load time 1 acknowledgement
04
Request load time 2 acknowledgement
05
Request key lock 1 acknowledgement
06
Request key lock 2 acknowledgement
07
Request key lock 3 acknowledgement
Function data
Door
Floor
Lift
Sub-function
Basic function
47 ... 40
39 ... 32
31 ... 24
23 ... 16
15 ... 8
7 ... 0