17
PARAMETER
37
Speed display
0, 0.01 to 9998
0
40
RUN key rotation
direction selection
0, 1
0
41
Up-to-frequency
sensitivity
0 to 100 %
10 %
42
Output frequency
detection
0 to 400 Hz
6 Hz
43
Output frequency
detection for reverse
rotation
0 to 400 Hz, 9999
9999
44
Second acceleration/
deceleration time
0 to 3600 s
5 s/10
*1
45
Second deceleration
time
0 to 3600, 9999
9999
46
Second torque boost
0 to 30 %, 9999
9999
47
Second V/F
(base frequency)
0 to 400 Hz, 9999
9999
48
Second stall
prevention
operation current
0 to 200 %, 9999
9999
51
Second electronic
thermal O/L relay
0 to 500 A, 9999
9999
52
DU/PU main display
data selection
0, 5, 8 to 12, 14,
20, 23 to 25,
52 to 55, 61, 62,
64, 100
0
55
Frequency monitoring
reference
0 to 400 Hz
50 Hz
56
Current monitoring
reference
0 to 500 A
Rated
inverter
current
57
Restart coasting time
0, 0.1 to 5 s, 9999
9999
58
Restart cushion time
0 to 60 s
1 s
59
Remote function
selection
0, 1, 2, 3
0
60
Energy saving control
selection
0, 9
0
65
Retry selection
0 to 5
0
66
Stall prevention
operation reduction
starting frequency
0 to 400 Hz
50 Hz
67
Number of retries at
alarm occurrence
0 to 10,
101 to 110
0
68
Retry waiting time
0.1 to 600s
1s
69
Retry count display
erase
0
0
Parameter Name
Setting Range
Initial Value
70
Special regenerative
brake duty
0 to 30 %
0 %
71
Applied motor
0, 1, 3, 13, 23, 40,
43, 50, 53
0
72
PWM frequency
selection
0 to 15
1
73
Analog input selection
0, 1, 10, 11
1
74
Input filter time
constant
0 to 8
1
75
Reset selection/
disconnected PU
detection/PU stop
selection
0 to 3, 14 to 17
14
77
Parameter write
selection
0, 1, 2
0
78
Reverse rotation
prevention selection
0, 1, 2
0
79
Operation mode
selection
0, 1, 2, 3, 4, 6, 7
0
80
Motor capacity
0.1 to 7.5 kW,
9999
9999
82
Motor excitation
current
0 to 500 A,
9999
9999
83
Motor rated voltage
0 to 1000 V
200 V/
400 V
*2
84
Rated motor
frequency
10 to 120 Hz
50 Hz
90
Motor constant (R1)
0 to 50 ,
9999
9999
96
Auto tuning
setting status
0, 11, 21
0
117
PU communication
station number
0 to 31
(0 to 247)
0
118
PU communication
speed
48, 96, 192, 384
192
119
PU communication
stop bit length
0, 1, 10, 11
1
120
PU communication
parity check
0, 1, 2
2
121
Number of PU
communication retries
0 to 10, 9999
1
122
PU communication
check time interval
0, 0.1 to 999.8 s,
9999
0
123
PU communication
waiting time setting
0 to 150 ms, 9999
9999
124
PU communication CR/
LF presence/absence
selection
0, 1, 2
1
125
Terminal 2 frequency
setting gain frequency
0 to 400 Hz
50 Hz
126
Terminal 4 frequency
setting gain frequency
0 to 400 Hz
50 Hz
127
PID control automatic
switchover
frequency
0 to 400 Hz, 9999
9999
Parameter Name
Setting Range
Initial Value
*1
Differs according to capacities.
5 s: FR-D720S-008SC to 100SC, FR-D740-080SC or less
10 s: FR-D740-120SC and 160SC
*2
The initial value differs according to the voltage class:
200 V/400 V