![Mitsubishi Electric FR-A700 Series Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/mitsubishi-electric/fr-a700-series/fr-a700-series_installation-manuallines_239203092.webp)
5 - 69
・
FR-D720-7.5K, SF1260
◎
Conducted interference
0
20
40
60
80
100
120
140
0.1
1
10
100
(Carrier frequency: 14.5kHz)
dB
(
V)
Frequency (MHz)
Peak value
EN61800 - 3 2nd Environment Category C3 QP level
(Note) The QP value will not exceed the peak value.
◎
Radiated interference(10m site)
(Note) FR-BIF and FR-BSF01(2-turn) are installed in the input side.
0
20
40
60
80
100
10
100
1000
(Carrier frequency: 14.5kHz)
dB
(
V)
EN61800 - 3 2nd Environment Category C3 QP level
Frequency (MHz)
Peak value
(Note) The QP value will not exceed the peak value.