![Mitsubishi Electric FR-A700 Series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/mitsubishi-electric/fr-a700-series/fr-a700-series_installation-manuallines_239203045.webp)
5 - 22
・
FR-A741-7.5K, SF1174
◎
Conducted interference
0
20
40
60
80
100
120
140
0.1
1
10
100
FR-A741-7.5K (Carrier frequency: 14.5kHz)
dB
(
V)
Frequency (MHz)
Peak value
EN61800 - 3 2nd Environment Category C3 QP level
(Note) The QP value will not exceed the peak value.
◎
Radiated interference(10m site)
0
20
40
60
80
100
10
100
1000
dB
(
V)
EN61800 - 3 2nd Environment Category C3 QP level
Frequency (MHz)
Peak value
FR-A741-7.5K (Carrier frequency: 14.5kHz)
(Note) The QP value will not exceed the peak value.