![Mitsubishi Electric DLP XD8100U Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/mitsubishi-electric/dlp-xd8100u/dlp-xd8100u_service-manual_240235075.webp)
- 5 -
(3) Warning dialog window
1. The warning dialog window displays the error location.
2. “ERROR TIME (SET TIME)” displays the time when the
warning history data were saved (,or the SET TIME in the
service menu). “ERROR TIME” and “SET TIME” shown in
the main dialog window are useful to know when the error
occurred.
3. Pressing the Detail button activates Notepad and opens
the file containing the information about the set and the
warning data. To prevent writing over this file, be sure to
select “Save As” from “File” of the menu in Notepad to
save the file. The name of the file being displayed should
be “DataTemp.txt.”
* For the warnings with “Identify the error by inputting
00EFp command.” displayed on the detailed report of
PCGC, see “Command list for acquiring the warning
history” (on the next page).
4. Pressing the Warning Clear button displays the
confirmation message window, which asks you whether
you will clear the warning history data. Press the OK
button to clear the warning history data or the Cancel
button to cancel clearing them.
5. Pressing the Back button displays the main dialog window
again and carries out communication with the projector
again to get information from it.
(4) Switching the COM port
1. Select the serial port to which the cable is being
connected. When the selected serial port isn’t available or
doesn’t exist, an error message window is displayed.
2. Press the OK button to switch the COM port. When the
serial port is switched correctly, communication with the
projector is carried out again to get information from it.
COM port switching dialog window
Goes back to the
main dialog window.
Clears all the
warning history data.
Creates a
detailed report.
All the error items are
displayed in red and their
check boxes are checked.
Indicates which data of the
Warning Status 1, 2, or 3 are
displayed.
Displays the SET TIME
when the warning history
data were saved.
Warning dialog window
The information to
be displayed varies
depending on the
model.
Содержание DLP XD8100U
Страница 9: ... 4 PCB LOCATION Fig 1 1 2 7 5 8 3 4 6 9 10 11 12 13 14 ...
Страница 11: ... 6 EXPOSED VIEW Fig 2 1 5 3 Fx1 Hx2 7 2 Dx2 Cx3 8 Ex1 Gx1 1 Ax1 4 6 Kx2 Jx1 Bx1 9 DLP ASSY ...
Страница 13: ... 8 Chassis ASSY 1 Fig 2 2 1 Ax10 Bx2 Cx2 4 5 Fx5 Gx2 Hx2 6 8 9 2 Kx5 Lx3 3 Dx2 7 Jx1 Ex2 ...
Страница 15: ... 10 1 Ax5 4 5 6 8 7 Bx2 Cx4 Dx2 Ex4 Hx2 11 2 3 10 9 Hx2 Fx1 Gx2 Chassis ASSY 2 Fig 2 3 ...
Страница 22: ... 17 1 2 3 4 5 6 7 8 9 10 E x 2 C x 2 D x 2 B x 2 A x 2 Filter ASSY Fig 2 7 ...
Страница 146: ... MEMO ...