Basic specifications 24
2.1.3. Abnormality detection function
This function detects abnormalities or deterioration of robot reduction gear components early.
Before the robot exhibits behavior that is a sign of an abnormality, the function can detect reduction gear or
encoder abnormalities.
Without adding sensors or an analysis personal computer, the robot controller alone can detect
abnormalities in reduction gear or the encoder.
Target parts
Output data
Reduction gear
Score (for each joint axis)
*Calculated when operating at 500 rpm or more
Encoder
Data Error
Score (for each joint axis)
Communication Error
Score (for each joint axis)
Battery
[Battery Voltage Status] (mechanical)
Information confirmation
Information
· Score: See above
· Log data for 365 days of Score
*1
· [Battery Voltage Status]: See above
· [Abnormality Detection Status]: Existence of abnormality detection of each target
part
Check method
RT ToolBox3 Predictive maintenance screen
(Refer to 5 Total score.,7 Abnormality detection function.)
[Parameters] (Refer to 14.3 Abnormality detection function
14.3.2 Data acquisition parameters. )
[Status Variable] (Refer to 13 Robot (system) status variables
13.3 Abnormality detection function.)
Setting/operation
Setting item
· How to Notify setting (abnormality detection): Warning Occurrence, Signal
Output
· Level Setting (reduction gear)
· Level Setting (encoder data error)
· Level Setting (encoder communication error)
· ["I/O Signals assignment"]
Setting method
RT ToolBox3 Predictive maintenance screen
(Refer to 3.2.1 Setting how to notify, 3.2.2 Setting detection level.)
[Parameters] (Refer to 14.3 Abnormality detection function
Operation item
· Maintenance Reset (reset of encoder abnormality level score)
· [Notification Pause]
Operation method
RT ToolBox3 Predictive maintenance screen
(Refer to 11.1 Warning Pause, 11.2 Maintenance Reset.)
[Parameters] (Refer to 14.3 Abnormality detection function
[I/O Signal]
*2
(Refer to 15 Dedicated input/output signals
15.2 Abnormality detection function.)
Notification
Notification content
· [Abnormality Detection Status] (abnormality detection): Output for each joint axis.
Notification method
RT ToolBox3 Predictive maintenance screen
*3
(Refer to 3.2.1 Setting how to
Warning Occurrence
*2
(Refer to 3.2.1 Setting how to notify.)
Signal Output
*2
(Refer to 3.2.3 Setting signals.)
*1 Displays the data for the most recent 365 days. Old data is overwritten.
*2 Setting is required.
*3 A maintenance message is displayed.
* For notification of a battery voltage drop, a warning is output by the standard function.
* For models and joint axes subject to this function, refer to "2.1.4 Target models/target axes".
Содержание CR800-D Series
Страница 2: ......
Страница 7: ... Revisions Revision Date Instruction Manual No Revision Details 2019 04 25 BFP A3663 First print ...
Страница 25: ...Basic specifications 23 MEMO ...
Страница 31: ...Basic specifications 29 MEMO ...
Страница 49: ...Startup and initial settings 47 MEMO ...
Страница 57: ...Consumption degree calculation function 55 MEMO ...
Страница 63: ...Operating information 61 MEMO ...
Страница 91: ...Maintenance 89 MEMO ...
Страница 193: ...Troubleshooting 191 ...
Страница 194: ...Apr 2019 MEE Printed in Japan on recycled paper Specifications are subject to change without notice ...