MEES19K187
PQH
Y
-P
-T
(S)L
MU-A1
, Y(S)L
M
U-A1
93
7. CAPACITY TABLES
WY-Series
PQHY-P240T(S)LMU/Y(S)LMU-A1
PQHY-P216T(S)LMU/Y(S)LMU-A1
Cooling
Heating
50
100
200
150
250
300
1.2
1.0
0.8
0.6
0.4
1.0
0.8
0.6
0.4
0.2
Total capacity of indoor units
Ratio of capacity
Ratio of power input
Cooling
Heating
100
150
250
200
300
350
1.2
1.0
0.8
0.6
0.4
1.0
0.8
0.6
0.4
0.2
Total capacity of indoor units
Ratio of capacity
Ratio of power input
Nominal
cooling
capacity
Rated
cooling
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P240TLMU/YLMU
PQHY-
240,000
70.3
21.14
228,000
66.8
19.49
18.74
Non-Ducted
Ducted
Input
Input
Nominal
Heating
capacity
Rated
Heating
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P240TLMU/YLMU
PQHY-
270,000
79.1
15.12
258,000
75.6
13.93
14.62
Non-Ducted
Ducted
Input
Input
Nominal
cooling
capacity
Rated
cooling
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P240TSLMU/YSLMU
PQHY-
240,000
70.3
16.89
228,000
66.8
15.57
16.15
Non-Ducted
Ducted
Input
Input
Nominal
Heating
capacity
Rated
Heating
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P240TSLMU/YSLMU
PQHY-
270,000
79.1
14.58
258,000
75.6
13.45
12.02
Non-Ducted
Ducted
Input
Input
Nominal
cooling
capacity
Rated
cooling
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P216TLMU/YLMU
PQHY-
216,000
63.3
19.23
206,000
60.4
17.72
16.10
Non-Ducted
Ducted
Input
Input
Nominal
Heating
capacity
Rated
Heating
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P216TLMU/YLMU
PQHY-
243,000
71.2
13.04
232,000
68.0
12.01
12.34
Non-Ducted
Ducted
Input
Input
Nominal
cooling
capacity
Rated
cooling
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P216TSLMU/YSLMU
PQHY-
216,000
63.3
14.03
206,000
60.4
12.93
13.24
Non-Ducted
Ducted
Input
Input
Nominal
Heating
capacity
Rated
Heating
capacity
BTU/h
kW
kW
BTU/h
kW
kW
P216TSLMU/YSLMU
PQHY-
243,000
71.2
12.88
232,000
68.0
11.88
10.35
Non-Ducted
Ducted
Input
Input
0000005752.BOOK 93 ページ 2020年2月28日 金曜日 午前10時8分