Low noise design
Optional drain pump
For PEFY-P VMS1, the drain pump is equipped as a standard
feature and eliminates the need for a drain trap. It has a
maximum lifting height of 550 mm.
For PEFY-P VMS1L-E, the drain pump is sold separately.
*For places where low noise operation is especially required (i.e., hotels), VMS1L
(without drain pump) is recommended.
P15 P20 P25 P32 P40 P50 P63
990
790
1190
200
Height
Width
mm
mm
PEFY-P VMS1(L)-E
Capacity
P15
28
24
22
P20
29
25
23
P25
30
26
24
P32
32
27
24
P40
33
30
28
P50
35
32
30
P63
36
33
30
Sound
pressure
level
dB(A)
High
Mid
Low
Fan
Speed
Drain pump
ensures a
lifting height
of up to
550 mm
790 mm, 99
0 mm, 1190
mm
Height
200 mm
(all models)
The thin body with a height of no more than 200 mm (all models)
allows installation in a ceiling with small cavity space.
Compact design with a height of no
more than 200 mm
(all models)
and widths
of 790 mm
(P15-P32)
.
External static pressure can be selected from 5, 15, 35 and
50 Pa (set to 15 Pa at the time of factory shipment).
Demonstrates a maximum external static
pressure of 50 Pa despite its compact
design
Owing to a centrifugal fan and coil, low noise operation is
realized. It is best suited to places where quietness is required.
• Sound pressure level (standard static pressure)
at 15 Pa
Ceiling concealed type
Low static pressure type
*This image shows the VMS1 type
(equipped with a drain pump as a standard feature).
PEFY-P VMS1(L)-E
• Technologies and functions
∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167
A thin body 200 mm in height and a maximum external static
pressure rating of 50 Pa provides significant flexibility of design
and allows installation in narrow ceiling spaces.
The lineup consists of models up to P63 with the same height.
Optional
VMS1L
VMS1
PEFY-P15VMS1(L)-E PEFY-P20VMS1(L)-E PEFY-P25VMS1(L)-E PEFY-P32VMS1(L)-E PEFY-P40VMS1(L)-E PEFY-P50VMS1(L)-E PEFY-P63VMS1(L)-E
Power source
1-phase 220-240V 50Hz / 1-phase 220-240V 60Hz
Cooling capacity
*1
kW
1.7
2.2
2.8
3.6
4.5
5.6
7.1
*1 BTU/h
5,800
7,500
9,600
12,300
15,400
19,100
24,200
Heating capacity
*1
kW
1.9
2.5
3.2
4.0
5.0
6.3
8.0
*1 BTU/h
6,500
8,500
10,900
13,600
17,100
21,500
27,300
Power
*3 Cooling
kW
0.05 [0.03]
0.05 [0.03]
0.06 [0.04]
0.07 [0.05]
0.07 [0.05]
0.09 [0.07]
0.09 [0.07]
consumption
Heating
kW
0.03 [0.03]
0.03 [0.03]
0.04 [0.04]
0.05 [0.05]
0.05 [0.05]
0.07 [0.07]
0.07 [0.07]
Current
*3 Cooling
A
0.42 [0.31]
0.47 [0.36]
0.50 [0.39]
0.50 [0.39]
0.56 [0.45]
0.67 [0.56]
0.72 [0.61]
Heating
A
0.31 [0.31]
0.36 [0.36]
0.39 [0.39]
0.39 [0.39]
0.45 [0.45]
0.56 [0.56]
0.61 [0.61]
External fi nish
Galvanized
Dimension
mm
200 x 790 x 700
200 x 990 x 700
200 x 1,190 x 700
H x W x D
in.
7-7/8 x 31-1/8 x 27-9/16
7-7/8 x 39 x 27-9/16
7-7/8 x 46-7/8 x 27-9/16
Net weight
*3 kg(lbs.)
19(42) [18(40)]
20(45) [19(42)]
24(53) [23(51)]
28(62) [27(60)]
Heat exchanger
Cross fi n (Aluminium fi n and copper tube)
FAN
Type x Quantity
Sirocco fan x 2
Sirocco fan x 3
Sirocco fan x 4
Airfl ow rate
m
3
/min
5-6-7
5.5-6.5-8
5.5-7-9
6-8-10
8-9.5-11
9.5-11-13
12-14-16.5
(Lo-Mid-Hi)
L/s
83-100-117
91-108-133
91-117-150
100-133-167
133-158-183
158-183-217
200-233-275
cfm
176-212-247
194-229-282
194-247-317
212-282-353
282-335-388
335-388-459
424-494-583
External static press.
Pa
5-15-35-50
Motor
Type
DC motor
Output
kW
0.096
Air fi lter
PP Honeycomb fabric (washable)
Refrigerant
Gas
mm(in.)
ø12.7 (ø1/2) Brazed
ø15.88 (ø5/8) Brazed
pipe diameter
Liquid
mm(in.)
ø6.35 (ø1/4) Brazed
ø9.52 (ø3/8) Brazed
Field drain pipe diameter
mm(in.)
O.D. 32 (1-1/4)
Sound pressure level
dB<A>
22-24-28
23-25-29
24-26-30
24-27-32
28-30-33
30-32-35
30-33-36
(Lo-Mid-Hi)
(mesured in anechoic room)
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor : 27°CD.B./19°CW.B. (81°FD.B. / 66°FW.B.) Outdoor : 35°CD.B. (95°FD.B. )
Heating : Indoor : 20°CD.B. (68°FD.B.) Outdoor : 7°CD.B. / 6°CW.B. (45°FD.B. / 43°FW.B.)
Pipe length : 7.5m (24-9/16ft) Height diff erence : 0m (0ft)
*2 The external static pressure is set to 15 Pa at factory shipment.
*3 [ ] is in case of PEFY-P15-63VMS1L-E
Notes:
Optional parts
Description
Model
Applicable capacity
Drain pump
PAC-KE07DM-E
P15, 20, 25, 32, 40, 50, 63 *For PEFY-VMS1L only
Control box replace kit
PAC-KE70HS-E
P15, 20, 25, 32, 40, 50, 63
Ceiling concealed type
Low static pressure type
PEFY-P VMS1(L)-E
135
VRF
Y-Series
VRF
Lineup
VRF
R2-Series
VRF
Zubadan
VRF
WY-Series
VRF
WR2-Series
VRF
S-Series
VRF
Indoor Units
Ventilation
Systems
Technologies and Functions
Remote Controller
Hot Water Solution
VRF
BC Controllers
VRF
S-Series
SPECIFICATIONS
Содержание City Multi R2 Series
Страница 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Страница 101: ...BC Controllers 101 ...
Страница 112: ...Indoor Units VRF 112 ...
Страница 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Страница 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Страница 128: ...Ceiling Concealed Type 128 ...
Страница 150: ...Wall Mounted Type 150 ...
Страница 154: ...Floor Standing Type 154 ...
Страница 181: ...Ventilation Systems 181 ...
Страница 190: ...Remote Controllers 190 ...
Страница 214: ...Hot Water Solution Air to Water Series 214 ...