MEES19K180
PURY-HP-T(S)NU-A, Y(S)NU-A
10
1. SPECIFICATIONS
Hyper Heating Inverter R2-Series
Outdoor Model
PURY-HP120YNU-A
Indoor Model
Non-Ducted
Ducted
Power source
3-phase 3-wire 460 V ±10% 60 Hz
Cooling capacity
*1 BTU/h
120,000
(Nominal)
kW
35.2
Power input
kW
8.82
(460) Current input
A
12.3
(Rated)
BTU/h
114,000
kW
33.4
Power input
kW
8.04
8.29
(460) Current input
A
11.2
11.5
Temp. range of
Indoor
W.B.
59~75°F (15~24°C)
cooling
Outdoor
D.B.
23~126°F (-5~52°C)
Heating capacity
*2 BTU/h
135,000
(Nominal)
kW
39.6
Power input
kW
10.07
(460) Current input
A
14.0
(Rated)
BTU/h
129,000
kW
37.8
Power input
kW
9.01
9.63
(460) Current input
A
12.5
13.4
Temp. range of
Indoor
D.B.
59~81°F (15~27°C)
heating
Outdoor
W.B.
-22~60°F (-30~15.5°C)
Indoor unit
Total capacity
50~150% of outdoor unit capacity
connectable
Model/Quantity
P04~P96/1~30
Sound pressure level (measured in anechoic room) *3 dB <A>
64.0/65.0
Sound power level (measured in anechoic room) *3
dB <A>
84.0/85.0
Refrigerant
High pressure
in. (mm)
3/4 (19.05) Brazed
piping diameter
Low pressure
in. (mm)
1-1/8 (28.58) Brazed
Minimum Circuit Ampacity
A
21
Maximum Overcurrent Protection
A
35
FAN
Type x Quantity
Propeller fan x 2
Airflow rate
cfm
9,550
m
3
/min
270
L/s
4,500
Control, Driving mechanism
Inverter-control, Brushless DC motor
Motor output
kW
0.46+0.46
*4 External static press.
0 in.WG (0 Pa)
Compressor
Type x Quantity
Inverter scroll hermetic compressor x 1
Manufacture
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Starting method
Inverter
Motor output
kW
7.8
Case heater
kW
-
Lubricant
MEL46
External finish
Pre-coated galvanized steel sheet
<MUNSELL 5Y 8/1>
External dimension H x W x D
in.
71-5/8 x 49-1/4 x 29-3/8
mm
1,818 x 1,250 x 745
Protection
High pressure protection
High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
devices
Inverter circuit (COMP./FAN)
Over-heat protection, Over-current protection
Fan motor
-
Refrigerant
Type x original charge
R410A x 23 lbs + 12 oz (10.8 kg)
Control
Indoor LEV and BC controller
Net weight
lbs (kg)
697 (316)
Heat exchanger
Salt-resistant cross fin & copper tube
HIC circuit (HIC: Heat Inter-Changer)
-
Defrosting method
Auto-defrost mode (Reversed refrigerant cycle)
Drawing
External
KB94C0H0
Wiring
KE94G817
Standard
Document
Installation Manual
attachment
Accessory
Details refer to External Drw
Optional parts
joint: CMY-Y102SS-G2,CMY-Y102LS-G2,CMY-R160-J1,CMY-R201,202,203,301,306S-G,CMY-R302,303,304,305S-G1
BC controller: CMB-P104,106,108,1012,1016NU-J1
Main BC controller: CMB-P108,1012,1016NU-JA1,CMB-P1016NU-KA1
Sub BC controller: CMB-P104,108NU-KB1
Remarks
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred
to the Installation Manual.
Notes:
Unit converter
1.Nominal cooling conditions (Test conditions are based on AHRI 1230)
Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)
2.Nominal heating conditions (Test conditions are based on AHRI 1230)
Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.)
3.Cooling mode/Heating mode
4.External static pressure option is available (0.12 in.WG, 0.24 in.WG, 0.32 in.WG/30 Pa, 60 Pa, 80 Pa).
BTU/h
=kW x 3,412
cfm
=m
3
/min x 35.31
lbs
=kg/0.4536
*Above specification data is
* Due to continuing improvement, above specifications may be subject to change without notice.
subject to rounding variation.
0000005744.BOOK 10 ページ 2020年2月25日 火曜日 午後5時19分