background image

Module :

 

PUHY-P120TKMU-A or 144TKMU-A – DIMENSIONS

(7/8)

(1-3/4)

(1-3/8)

(2-15/32)

(1-1

1/32)

(2-1/16)

(2-9/16)

(3-23/32)

(5-29/32)

(5-17/32)

(3-1/16)

(1/2)

(1/2)

(1-1/8)

(1-1/8)

(3/8)

(1/2)

Fan box 

ø12.7 Brazed

ø12.7

ø28.58 Brazed

ø28.58

ø9.52 Brazed

Note1.Please refer to the next page for information            regarding necessary spacing around the            unit and foundation work.         2.At brazing of pipes, wrap the refrigerant service valve             with wet cloth and keep the temperature of             refrigerant service valve under 120°C(248°F).

Refrigerant pipe

Service valve

Diameter

Model

Connecting pipe specifications

(ø12.7 Brazed)

PUHY

-P144TKMU

PUHY

-P120TKMU

Gas

Gas

3

(26-23/32~26-15/16)

(26-13/16)

(3-5/32)

(3-5/32)

=(5-29/32)X4

(2-25/32)

(11-15/16)

(4-25/32)

(5-23/32)

(3-5/16)

(1-3/16)

(1-3/16)

(3-23/32)

(5-31/32)

(7-23/32)

(8-9/16)

(3-17/32)

(3-1/16)

(23-5/8)

(25/32)

(25/32)

(13/16)

(13/16)

(2-1/4)

(2-1/4)

2

1

4

7

2X2-80(3-5/32)X35(1-13/32) Oval hole <Sling hole>

5

6

Discharge air

Intake air

Intake air

Service panel

Intake air

2X3-14(9/16)X20(13/16) Oval hole

(Mounting pitch)

(Mounting pitch)

(Mounting pitch)

Control box

Refrigerant service valve  <liquid> Refrigerant service valve  <gas>

Service panel

2X7-ø4.6(3/16) Hole (Make hole at the plastic fan guard  for snow hood attachment) <Snow hood attachment hole>

Refrigerant service  valve <gas>

Refrigerant service valve <liquid>

(6-25/32)

(8-25/32)

ø34 Knockout hole

ø52 Knockout hole

ø65 Knockout hole

ø43.7 or ø22.2 Knockout hole

ø62.7 or ø34.5 Knockout hole

150 × 94 Knockout hole

140 × 77 Knockout hole

Specifications

For transmission cables

For pipes

Bottom through hole

Front through hole

Usage

For wires

Front through hole

Front through hole

Bottom through hole

Bottom through hole

Front through hole

NO.

*1 Expand the on-site piping and connect to the refrigerant service valve piping. *2 Use the pipe joint(field supply) and connect to the refrigerant service valve piping.  *3 Indicates dimensions and connection specifications in the case the unit is       used in combination with other outdoor units.  *4 Furthest piping length (OU from IU)   40m(131ft)

*1 *3 *4

*2

*1

*2

58(2-5/16)

75(2-31/32) 541(21-5/16)

217

172

196

151

121

303

1347(53-1/16)

1650(64-31/32)

1750(68-29/32)

19.5

831(32-23/32)

831(32-23/32)

19.5

600=150X4

70

(740)(29-5/32)

29.5

29.5

562(22-5/32)

740(29-5/32)

77

89

80

795(31-5/16)

795(31-5/16)

80

681(678~684)

140(5-17/32)

49(1-15/16)

54(2-5/32)

57

20

586(23-3/32)

57

20

223

145

590(23-1/4)

83(3-9/32)

150(5-29/32)

561(22-3/32)

516(20-1

1/32)

84

94

Front view

Top view

Left side view

Bottom view

PUHY-P120,144TKMU-A(-BS)

Unit : mm(in.)

1

2

3

4

5

6

7

> =

Liquid

Liquid

Содержание City Multi PUHY-P120TKMU-A

Страница 1: ...stem Data Heating Power Input kW 19 26 Cooling Current 208 230V R L A 52 1 47 1 Refer to System Data Heating Current 208 230V R L A 59 4 53 7 Minimum Circuit Ampacity MCA A Refer to Module Data 45 42 34 31 Maximum Breaker Size A Refer to Module Data 50 40 Maximum Overcurrent Protection A Refer to Module Data 73 67 57 52 Piping Diameter Refer to System Data From Twinning Kit to Indoor Units Brazed ...

Страница 2: ...anual for details of Twinning pipe installation 3 The pipe section before the Twinning pipe sections a and b in the figure must have at least 500mm 19 11 16 of straight section including the straight pipe that is supplied with the Twinning pipe 4 Only use the Twinning pipe by Mitsubishi optional parts d or f c or e Gas Liquid P96 P120 Unit model Twinning pipe Outdoor unit Front view Left view To i...

Страница 3: ...ic fan guard for snow hood attachment Snow hood attachment hole Refrigerant service valve gas Refrigerant service valve liquid 6 25 32 8 25 32 ø34 Knockout hole ø52 Knockout hole ø65 Knockout hole ø43 7 or ø22 2 Knockout hole ø62 7 or ø34 5 Knockout hole 150 94 Knockout hole 140 77 Knockout hole Specifications For transmission cables For pipes Bottom through hole Front through hole Usage For wires...

Страница 4: ...ttachment Intake air Discharge air Refrigerant service valve gas Refrigerant service valve liquid Control box Intake air Service panel Intake air Sling hole 2 5 2X2 14 9 16 X20 13 16 Oval hole 2X2 80 3 5 32 X35 1 13 32 Oval hole 6 ø34 Knockout hole ø52 Knockout hole ø65 Knockout hole ø43 7 or ø22 2 Knockout hole ø62 7 or ø34 5 Knockout hole 150 94 Knockout hole 140 77 Knockout hole Specifications ...

Страница 5: ...ronmental protection set by the International Standard Organization ISO Twinning Kit CMY Y100CBK3 1 15 16 2 pcs 2 pcs 3 7 8 9 1 2 7 7 32 3 9 32 19 29 32 13 15 32 23 5 32 6 5 16 2 15 32 1 15 16 2 15 32 Distributer Distributer Pipe cover Dot dashed part 1 2 1 2 1 2 1 2 Local brazing Note 2 5 8 5 8 1 1 8 Note 2 1 7 8 1 7 8 Pipe cover Dot dashed part Local brazing 1 1 8 2 pcs 7 8 3 4 1 2 5 8 1 2 3 8 1...

Отзывы: