MEES21K108
PU
H
Y-
H
P-
T(
S)
N
U
-A
, Y
(S
)N
U
-A
4
1. SPECIFICATIONS
Hyper Heating Inverter Y-Series
Outdoor Model
PUHY-HP120TNU-A
Indoor Model
Non-Ducted
Ducted
Power source
3-phase 3-wire 208-230 V ±10% 60 Hz
Cooling capacity
*1 BTU/h
120,000
(Nominal)
kW
35.2
Power input
kW
8.53
(208-230) Current input
A
26.3-23.7
(Rated)
BTU/h
114,000
kW
33.4
Power input
kW
7.67
8.11
(208-230) Current input
A
23.6-21.3
25.0-22.6
Temp. range of
Indoor
W.B.
59~75°F (15~24°C)
cooling
Outdoor
D.B.
23~126°F (-5~52°C)
Heating capacity
*2 BTU/h
135,000
(Nominal)
kW
39.6
Power input
kW
9.63
(208-230) Current input
A
29.7-26.8
(Rated)
BTU/h
129,000
kW
37.8
Power input
kW
8.55
9.28
(208-230) Current input
A
26.3-23.8
28.6-25.8
Temp. range of
Indoor
D.B.
59~81°F (15~27°C)
heating
Outdoor
W.B.
-22~60°F (-30~15.5°C)
Indoor unit
Total capacity
50~130% of outdoor unit capacity
connectable
Model/Quantity
P04~P96/1~30
Sound pressure level (measured in anechoic room) *3 dB <A>
59.5/61.5
Sound power level (measured in anechoic room) *3
dB <A>
79.5/80.5
Refrigerant
Liquid pipe
in. (mm)
3/8 (9.52) Brazed (1/2 (12.7) Brazed, the farthest pipe length >= 40 m)
piping diameter
Gas pipe
in. (mm)
1-1/8 (28.58) Brazed
Minimum Circuit Ampacity
A
47-43
Maximum Overcurrent Protection
A
70-60
FAN
Type x Quantity
Propeller fan x 2
Airflow rate
cfm
7,750
m
3
/min
220
L/s
3,670
Control, Driving mechanism
Inverter-control, Brushless DC motor
Motor output
kW
0.46+0.46
*4 External static press.
0 in.WG (0 Pa)
Compressor
Type x Quantity
Inverter scroll hermetic compressor x 1
Manufacture
MITSUBISHI ELECTRIC
Starting method
Inverter
Motor output
kW
6.5 x 1
Case heater
kW
-
Lubricant
MEL46
External finish
Pre-coated galvanized steel sheet
<MUNSELL 3Y 7.8/1.1 or similar>
External dimension H x W x D
in.
71-5/8 x 49-1/4 x 29-3/8
mm
1,818 x 1,250 x 745
Protection
High pressure protection
High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
devices
Inverter circuit (COMP./FAN)
Over-current protection
Fan motor
-
Refrigerant
Type x original charge
R410A x 23 lbs + 12 oz (10.8 kg)
Control
LEV and HIC circuit
Net weight
lbs (kg)
655 (297)
Heat exchanger
Salt-resistant cross fin & copper tube
HIC circuit (HIC: Heat Inter-Changer)
Copper pipe, tube-in-tube structure
Defrosting method
Auto-defrost mode (Reversed refrigerant cycle)
Drawing
External
KB94C0GM
Wiring
KE94G811
Standard
Document
Installation Manual
attachment
Accessory
Details refer to External Drw
Optional parts
joint: CMY-Y102SS/102LS-G2, CMY-Y202S-G2
Header: CMY-Y104/108/1010C-G
Remarks
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be
referred to the Installation Manual.
Notes:
Unit converter
1.Cooling conditions (Test conditions are based on AHRI 1230)
Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)
2.Heating conditions (Test conditions are based on AHRI 1230)
Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.)
3.Cooling mode/Heating mode
4.External static pressure option is available (0.12 in.WG, 0.24 in.WG, 0.32 in.WG/30 Pa, 60 Pa, 80 Pa).
BTU/h =kW x 3,412
cfm
=m
3
/min x 35.31
lbs
=kg/0.4536
*Above specification data is
* Due to continuing improvement, above specifications may be subject to change without notice.
subject to rounding variation.