3

4.2

H

D

 

670

E

 

574

48

48

D

 

A

E

 

B

108

108

A

A

B

B

C

F

B

A

D

C

50

±

10

G

A

Nut

B

Washer (supplied with the unit body)

C

Hanging bolt ø10 (M10 screw)

D

Ceiling hole dimensions

E

Hanging bolt pitch

F

Hanging bolt

G

Finished ceiling surface

H

Hanging bracket

[Fig. 4.2.1]

6

6.3

[Fig. 6.2.1]

[Fig. 6.3.1]

6.1

F

A

B

C

C

D

E

68

70

68

476

606

178

70

333

222

38

235

192

255

290

338~353

More than 350

45

20

F

E

A

D

B

70

146

58

327

497

507

574

574

68

68

266

45

125

60

190

122

290

more than 350

20

A

Refrigerant pipe (liquid pipe): HP

B

Drain pipe

C

Hanging bolt pitch

*1

E

F

G

A

B

C

D

H

J

I

M

N

L

K

O

A

“0-0 gas” mark

B

“INNER” mark

C

“OUTER” mark

D

Flare insulation (2)

E

Refrigerant piping (gas)

F

Refrigerant piping (liquid)

G

Field refrigerant piping

H

Pipe insulation (1)

I

Insulation material

J

Flare

K

Pull in this direction.

L

Insulation material

M

Flare

N

There must be no gap.

O

Move to the original position.

[Fig. 6.3.2]

C

B

A

D

E

F

G

*2

20

20

20

20

*3

*4

A

B

C

A

Field refrigerant piping

B

There must be no gap.

C

Unit body plate

D

OUTER

E

INNER

F

Unit body

G

Provided flare insulation (2)

A

Tape (3)

B

Fasten with tape.

C

Provided tie band (4)

 (figure showing the flare insulation)

[Fig. 6.3.3]

[Fig. 5.1.1]

[Fig. 5.2.1]

A

D

C

B

A

Drain pipe side

B

Unit body

C

Packing cap

D

Lifting machine

A

A

A

Indoor unit’s bottom surface

(Surface to which a decorative panel is attached)

5

5.2

5.1

D

Refrigerant pipe (gas pipe): LP

E

Filling port

F

Drain hole

Model name

20~40

50 · 63

80 · 100

125

A

1040

1210

1710

1970

B

824

994

1494

1756

C

157~167

155 ~ 165

D

More than 350

6.2

[Fig. 6.1.1]

A

B

C

B

A

Flare cutting dimensions

B

Refrigerant pipe sizes & Flare nut tightening torque

C

Apply refrigerating machine oil over the entire flare seat surface

20-100

125

Содержание CITY MULTI PLFY-P-VLMD-E SERIES

Страница 1: ...E Per un uso sicuro e corretto leggere attentamente questo manuale di installazione prima di installare il condizionatore d aria INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert MANUAL DE INSTALAÇÃO Para segurança e utilização correctas leia atentamente este manual de instalação antes de instalar a ...

Страница 2: ... hole F 6 ø2 9 mounting hole G 4 ø2 9 mounting hole 3 2 Fig 3 2 1 Model name 20 40 50 63 80 100 125 A 1080 1250 1750 2010 B More than 1000 C More than 500 D Lap 20 E More than 350 F F B B 110 159 52 34 435 218 218 221 110 52 159 34 435 218 218 221 159 110 52 34 754 221 199 199 199 199 201 C E D 856 45 90 ø224 145 G 3 3 Fig 3 3 1 A E D B A E 2 216 45 197 240 1 1 C D 90 90 181 2 ø172 A 2 A 1 A Fresh...

Страница 3: ...sulation material J Flare K Pull in this direction L Insulation material M Flare N There must be no gap O Move to the original position Fig 6 3 2 C B A D E F G 2 20 20 20 20 3 4 A B C A Field refrigerant piping B There must be no gap C Unit body plate D OUTER E INNER F Unit body G Provided flare insulation 2 A Tape 3 B Fasten with tape C Provided tie band 4 figure showing the flare insulation Fig ...

Страница 4: ...7 2 1 Fig 7 2 2 Fig 7 3 1 Fig 8 1 1 D I C H G K I J 3 D C 28 cm D 170 5 mm G Drain hose Accessory s s s s s Be sure to use the supplied drain hose Accessory H Less than 300 mm I Hard vinyl chloride 90 elbow field supply J Hard vinyl chloride VP 25 field supply K Tie band small Accessory D D D E F 2 D Indoor unit E Take as large as possible About 10 cm F Collected pipes A C B A B 1 A 25 cm B 1 5 2 ...

Страница 5: ...al bed for M NET outdoor transmission cable Use shielding earth cable on outdoor unit side Fig 8 3 1 Fig 8 3 3 Viewed from bottom of the terminal bed box Power Source N L M1 M2 S L N 1 2 2 2 D D H E F F H E G G 2 1 S S M1 M2 Fig 8 3 2 Fig 8 3 4 CN62 SW1 MADE IN JAPAN ON SW14 N0 N0 W254613G03 FP AD P JP2 JP3 JP4 CN82 8 1 6 1 10 1 240V 220V SW5 JP1 SWC SWA 1 3 2 0 SW12 10 0 SW11 1 0 Fig 8 4 1 Addres...

Страница 6: ...air conditioner is installed in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit even if the refrigerant should leak Consult the dealer regarding the appropriate measures to prevent the safety limit from being exceeded Should the refrigerant leak and cause the safety limit to be exceeded hazards due to lack of oxygen in the room could res...

Страница 7: ...h conventional refriger ants Gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge refrigerant recovery equipment If the conventional refrigerant and refrigerator oil are mixed in the R410A or R407C the refrigerant may deteriorated If water is mixed in the R410A or R407C the refrigerator oil may deteriorate Since R410A or R407C does not contain ...

Страница 8: ...2 A Fresh air intake B Fresh air intake 240 45 knock out hole C Fresh air intake ø150 knock out hole D 4 ø2 9 mounting hole E Cut Notes 1 1 1 1 1 Make 4 cuts on the outdoor air inlet When connecting a round flexible duct mount an optional outdoor air intake duct flange PAC KH 110F ø150 2 2 2 2 2 The amount of suction air coming through the outdoor air inlet can be adjusted by making two cuts on th...

Страница 9: ...ovided pipe insula tion 1 on the liquid pipe of the refrigerant piping and then mount the flare insulation 2 on the gas pipe Fixing of insulated pipe Fixing of flare insulation Reference drawing Fig 6 3 1 P 3 Fig 6 3 2 P 3 Fig 6 3 2 P 3 Fig 6 3 3 P 3 Note 3 Fig 6 3 3 P 3 Note 4 Detail of work INNER and OUTER are marked on the in side of the flare insulation Mount the portion marked INNER near the ...

Страница 10: ...ate Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing If dust dirt or water gets into the refrigerant cycle the oil will deteriorate and the compressor may fail Use Suniso 4GS or 3GS small amount refrigerator oil to coat the flare and flange connection part For models using R22 Use ester oil ether oil or alkylbenzene small amo...

Страница 11: ...he polyethylene plug C About 1000 cc D Water E Filling port 6 Never connect the power cable to leads for the transmission cables Otherwise the cables would be broken 7 Be sure to connect control cables to the indoor unit remote controller and the outdoor unit 8 Put the unit to the ground on the outdoor unit side 9 Select control cables from the conditions given in below Caution Be sure to put the ...

Страница 12: ...it installation manual Install a remote controller following the manual supplied with the remote con troller Connect the 1 and 2 on indoor unit TB15 to a MA remote controller Non polarized 2 wire Connect the M1 and M2 on indoor unit TB5 to a M NET remote controller Non polarized 2 wire Connect the remote controller s transmission cable within 10 m using a 0 75 mm2 core cable If the distance is mor...

Страница 13: ...e contact address telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Отзывы: