![Mitel Aastra 470 Скачать руководство пользователя страница 195](http://html.mh-extra.com/html/mitel/aastra-470/aastra-470_system-manual_1807623195.webp)
Configuration
195
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014
– The restart is triggered immediately. All the active call and data con-
nections are interrupted.
First start of the communication server
A first start has the effect of resetting the communication server from scratch. The
system-specific data such as the system ID, system type, sales channel, licence
code, software generation and IP address of the system are preserved.
A restart can be achieved in the following ways:
• Using the control panel on the front panel
See
"Call-Manager display and control panel", page 224
• With WebAdmin in the maintenance settings
With the
First start
button in the
System reset
(
=4e
) view.
Notes:
– A first start deletes all the configuration data already stored and
replaces it with the default values of the sales channel. You should
therefore always back up the configuration data prior to a first start by
using a data backup .
– The first start is triggered immediately. All the active call and data con-
nections are interrupted.
Starting the communication server for the first time and resetting the
sales channel
With the
First start and reset sales channel
button for the maintenance settings in
the WebAdmin
System reset
(
=4e
) view, you have the possibility for a first start to
also delete the sales channel and licence code. During the next start, you will be
prompted for the sales channel and licence code. Note that the licence code is de-
pendent on the sales channel and that you can no longer use the existing licence
code.
Note:
This function is only accessible for Administrators in Expert mode.