10
The
following
lists
all
POST
Fault
Code
conditions:
POST
Fault
Code
Description
1
User
invoked
Settings
Default
to
Factory
Settings
warning
2
LCD
Terminal
Fault
/
LCD
is
attached
and
a
DIP
Switch
is
ON
3
Barometric
sensor
Fault
/
No
communication
reply
4
Barometric
sensor
Fault
/
Prom
CRC
Mismatch
5
Barometric
pressure
Fault
/
Pressure
<
10
mbar
or
>
1200
mbar
6
Temperature
Fault
/
Temperature
<
‐
40
deg.
C
or
>
85
deg.
C
7
Low
Battery
Lockout
Fault
/
Battery
<
Low
Voltage
Lockout
Level
8
Ambient
Barometric
Fault
/
Unstable
conditions
during
Launch
Commit
Test
POST
Code
Notes:
‐
Code
1
is
beeped/flashed
whenever
the
user
performs
a
Factory
Default
Operation.
‐
Code
2
is
beeped
flashed
if
you
connect
the
LCD
Terminal
with
a
DIP
Switch
in
the
ON
position.
‐
Codes
3
thru
6
indicate
a
hardware
fault.
Contact
Missile
Works
for
warranty
or
service
details.
‐
Code
7
indicates
the
battery
is
at/
below
the
specified
Low
Voltage
Lockout.
Replace
your
battery.
‐
Code
8
indicates
that
ambient
baro
conditions
are
unstable
for
the
currently
programmed
Arming
Altitude.
Either
raise
the
Arming
Altitude
setting,
or
consider
flying
in
more
stable
conditions.
Audio
Options
Report
Mode
If
you
have
enabled
any
of
the
Pre
‐
Launch
Audio
options
of
the
RRC3,
they
will
be
beeped/flashed
at
this
stage
of
operations.
These
audio
options
include
beeping/flashing
of
battery
voltage
and
Deployment
modes.
(see
the
following
“Base
Settings”
section
if
the
manual
for
more
details).
Launch
Commit
Test
The
Launch
Commit
Test
is
a
10
second
test
operation
that
is
a
“trial
run”
of
the
Launch
Detect
Mode,
applying
the
currently
programmed
Arming
Altitude
against
ambient
conditions.
Should
ambient
conditions
be
such
that
a
Launch
Detect
condition
is
valid
during
this
test
period,
the
RRC3
will
invoke
a
POST
Code
8
condition
(see
above).
During
the
Launch
Commit
Test,
the
LED
flashes
on
and
off
at
a
1
second
rate.
Launch
Detect
Mode
When
all
previous
modes
are
complete,
the
unit
transitions
into
Launch
Detect
Mode.
The
piezo
and
the
LED
will
beep/flash
to
indicate
the
continuity
status
of
the
drogue
and
main
output
terminals
every
5
seconds
as
follows:
Long
Beep/Flash
No
continuity
on
Drogue
or
Main
1
Short
Beep
Continuity
on
Drogue
only
2
Short
Beeps
Continuity
on
Main
only
3
Short
Beeps
Continuity
on
Drogue
and
Main
The
RRC3
monitors
the
barometric
sensor
for
a
change
in
altitude
as
specified
by
the
current
Arming
Altitude
setting
to
determine
the
launch
of
the
rocket.
As
soon
the
the
current
altitude
exceeds
the
Arming
Altitude,
the
RRC3
is
activated
and