background image

Copyright 2002

Miranda Technologies Inc.

Specifications may be subject to change.

Printed in Canada

August 2002

SER

-800D

SER

-810E

SER-800D

SER-810E

Guide to Installation

and Operation

M398-9900-101

HD Video

Deserializer/

Serializer

Miranda

Technologies inc.

3499 Douglas-B.-Floreani

St-Laurent, Québec, Canada H4S 1Y6

Tel. 514-333-1772

Fax. 514-333-9828

www.miranda.com

Содержание SER-800D

Страница 1: ... Printed in Canada August 2002 SER 800D SER 810E SER 800D SER 810E Guide to Installation and Operation M398 9900 101 HDVideo Deserializer Serializer Miranda Technologies inc 3499 Douglas B Floreani St Laurent Québec Canada H4S 1Y6 Tel 514 333 1772 Fax 514 333 9828 www miranda com ...

Страница 2: ...for a period of two 2 years from the date of shipment from the factory If equipment fails due to such defects Miranda will pro vide repair of the failed unit under the terms of the Miranda warranty If the equipment has been proven to be defective on arrival Miranda will ship a new product in exchange usually within 36 hours of factory notification If the equipment to be repaired is essential and t...

Страница 3: ...e a new product at current retail prices The Buyer will pay freight and insurance charges for the return of the defective prod uct or part to the manufacturer for repair Miranda Technologies will pay freight and insurance charges for the return of the repaired product or part to the Buyer Out Of Warranty Equipment Updates and Spare Parts Policy Miranda Technologies current pricing structure for ou...

Страница 4: ...22 226 Rue De Rosny 3499 Douglas B Floreani 93100 Montreuil St Laurent Montreal Que H4S 1Y6 France Canada Tel 1 514 333 1772 33 1 55 86 87 88 Fax 1 514 333 6914 33 1 55 86 00 29 Toll free 1 800 224 9828 www miranda com Miranda Asia Mita Nexus Bldg 2F 1 3 33 Mita Minato Ku Tokyo Japan 108 0073 81 3 5730 2988 81 3 5730 2973 ...

Страница 5: ...iv SER 800D 810E Guide to Installation and Operation ...

Страница 6: ...ew 4 2 3 SER 810E Installation 4 3 Operation 5 3 1 Powering Up 5 3 2 SER 800D Operation 5 3 2 SER 810E Operation 5 3 4 Mode Selection 6 3 5 Status LED 7 4 SER Accessories 9 4 1 SER WSU Power Supply 9 4 2 SER CPS Centralized Power Supply Frame 9 4 2 1 SER CPS Front Panel 10 4 2 2 SER CPS Rear Panel 10 4 2 3 Installation 11 4 2 4 Locating and replacing a defective power supply 12 4 3 DB 50 Cable Con...

Страница 7: ...SER 800D E Guide to Installation and Operation vi ...

Страница 8: ... equipment Powered by wall plug in or rack mounted SER CPS for up to 10 coders Automatic format detection 2 serial HD SDI outputs SER 800D Jitter removal circuitry SER 810E Supports the following formats 720p 23 98 24 25 29 29 97 30 50 59 94 60 Hz frame freq 1035i 59 94 60 Hz field freq 1080sF 23 98 24 Hz frame freq 1080p 23 98 24 25 29 29 97 30 Hz frame freq 1080i 50 59 94 60 Hz field freq 1 3 Un...

Страница 9: ...SER 800D 810E Guide to Installation and Operation 2 ...

Страница 10: ...ll View of the SER 800D 2 2 SER 800D Installation To install the SER 800D directly on the destination equipment refer to the following diagram Figure 2 2 Connecting the SER 800D 2 3 SER 810E Overview SER 800D 810E Guide to Installation and Operation 3 Destination HD SDI video equipment DC Power supply Loop through input Loop through BNC connector Input BNC connector Mode slide switch Mounting scre...

Страница 11: ... Overall View of the SER 810E 2 4 SER 810E Installation To install the SER 810E directly on the source equipment refer to the following diagram Figure 2 4 Connecting the SER 810E OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 810E MODE Output BNC connectors Mode slide switch Mounting screws Status LED DC power input connector 50 pin input connector OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALI...

Страница 12: ...o signal is output by the D SUB 50 connector You can attach the SER 800D directly to the destina tion equipment by securing the mounting screws to the destina tion equipment female connector The output conforms to SMPTE 260M for 1035i format 296M for 720p format 274M and 295M for 1080sF 1080i and 1080p formats 3 3 SER 810E Operation Parallel HD Video Input Connect a HD parallel video signal to the...

Страница 13: ... SUB 50 pin out SER 800D 810E Guide to Installation and Operation 6 Pin Signal Pin Signal Pin Signal 1 CLK 34 CLK 2 Data9 18 Data1 35 Data9 3 Data8 19 Data1 36 Data8 4 Data7 20 Data0 37 Data7 5 Data6 21 Data0 38 Data6 6 Data5 22 GND 39 Data5 7 Data4 23 GND 40 Data4 8 Data3 24 GND 41 Data3 9 Data2 25 GND 42 Data2 10 Data19 26 Data11 43 Data19 11 Data18 27 Data11 44 Data18 12 Data17 28 Data10 45 Dat...

Страница 14: ...low ing lists the possible situations Green Indicates that the SER 800D 810E is powered and has detected a valid HD parallel video input signal Red Indicates an error with the input signal has been detected or simply there is no input cable connected Off The unit is not powered on Check that it is connected to the power supply and the power supply is properly connected to a power source Pin Signal...

Страница 15: ...SER 800D 810E Guide to Installation and Operation 8 ...

Страница 16: ...4 2 SER CPS Centralized Power Supply Frame Miranda s SER CPS Centralized Power Supply Frame can power up to 10 SER coders A male to male power plug connector is used for the connection between an SER coder and a DC output jack Refer to figure 4 1 DC Power connector pinout for the prop er pinout Figure 4 1 DC Power connector pinout 5 1VDC Ground digital and earth grounds connected together Plug spe...

Страница 17: ... frame Power Fail Indicator Flashes continuously when one of the frame s internal power supplies becomes defective The redundant power supply takes control during this time Rack Mount Holes Four rack mount holes are available for rack mounting 4 2 2 SER CPS Rear Panel Figure 4 3 describes the SER CPS back panel Figure 4 3 SER CPS Rear Panel SER Power Frame POWER FAIL POWER ON Rack mount holes Powe...

Страница 18: ...Both 110 VAC and 220 VAC standards supported Air Vents Keep free from obstruction in order to maintain proper ventilation 4 2 3 Installation Figure 4 4 describes a typical SER CPS installation Figure 4 4 SER CPS Connections OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER ...

Страница 19: ...wer supply A flashing LED indicates its designated power supply is defective Use the following diagram to locate the defective power supply 3 Once the defective power supply has been located unplug the unit 4 Remove the cable that connects to the defective power supply 5 Remove the four screws that attach the power supply to the frame 6 Replace the defective power supply with a new one and recon n...

Страница 20: ...ector end installed on the SER 800D 810E coder is male use the female to female cable adapter provided For cables longer than a few meters twisted pairs should be used for each signal and its return Make sure to connect both ends of the cable in a pin to pin for mat connect pin 1 of source connector to pin 1 of destination connector pin 2 to pin 2 pin 50 to pin 50 For a detail of the connector pin...

Страница 21: ...SER 800D 810E Guide to Installation and Operation 14 ...

Страница 22: ... freq SMPTE 260M 1080sF 23 98 24 Hz frame freq SMPTE 274M 1080p 23 98 24 25 29 29 97 30 Hz frame freq SMPTE 274M 1080i 50 59 94 60 Hz field freq SMPTE 274M and 295M Max cable length 2 m 6 Connector D SUB 50 Panasonic or Philips pin out user selectable Outputs SER 800D HD parallel video signal 720p 23 98 24 25 29 29 97 30 50 59 94 60 Hz frame freq SMPTE 296M 1035i 59 94 60 Hz field freq SMPTE 260M ...

Страница 23: ...75 ohm Mechanical Dimensions Width 67mm 2 63 Height 20 mm 0 8 Depth 85 mm 3 35 Weight 140g 5oz SER WSU Power Supply regulated Voltage 5 1VDC 0 1VDC Max Current 2 4 A Max Ripple 50mV Connector 2 5mm 5 5mm Plug SER CPS Power Supply Voltage 85 264VAC 47 400Hz Max Power 60W Dimensions Width 483mm 19 Height 1 RU Depth 175mm 6 9 Weight 4kg 8 8lbs NOTE All specifications are subject to change without not...

Страница 24: ...ouglas B Floreani St Laurent Québec Canada H4S 1Y6 Tel 514 333 1772 Fax 514 333 9828 www miranda com Copyright 2002 Miranda Technologies Inc Specifications may be subject to change Printed in Canada August 2002 SER 800D E SER 800D E ...

Страница 25: ...or a period of two 2 years from the date of shipment from the factory If equipment fails due to such defects Miranda will pro vide repair of the failed unit under the terms of the Miranda warranty If the equipment has been proven to be defective on arrival Miranda will ship a new product in exchange usually within 36 hours of factory notification If the equipment to be repaired is essential and th...

Страница 26: ...a new product at current retail prices The Buyer will pay freight and insurance charges for the return of the defective prod uct or part to the manufacturer for repair Miranda Technologies will pay freight and insurance charges for the return of the repaired product or part to the Buyer Out Of Warranty Equipment Updates and Spare Parts Policy Miranda Technologies current pricing structure for out ...

Страница 27: ...22 226 Rue De Rosny 3499 Douglas B Floreani 93100 Montreuil St Laurent Montreal Que H4S 1Y6 France Canada Tel 1 514 333 1772 33 1 55 86 87 88 Fax 1 514 333 6914 33 1 55 86 00 29 Toll free 1 800 224 9828 www miranda com Miranda Asia Mita Nexus Bldg 2F 1 3 33 Mita Minato Ku Tokyo Japan 108 0073 81 3 5730 2988 81 3 5730 2973 ...

Страница 28: ...SER 800D E Guide to Installation and Operation iv ...

Страница 29: ...4 2 3 SER 800E Installation 4 3 Operation 5 3 1 Powering Up 5 3 2 SER 800D Operation 5 3 2 SER 800E Operation 5 3 4 Mode Selection 6 3 5 Status LED 7 4 SER Accessories 9 4 1 SER WSU Power Supply 9 4 2 SER CPS Centralized Power Supply Frame 9 4 2 1 SER CPS Front Panel 10 4 2 2 SER CPS Rear Panel 10 4 2 3 Installation 11 4 2 4 Locating and replacing a defective power supply 12 4 3 DB 50 Cable Constr...

Страница 30: ...SER 800D E Guide to Installation and Operation vi ...

Страница 31: ...onnector of source equipment Powered by wall plug in or rack mounted SER CPS for up to 10 coders Automatic format detection 2 serial HD SDI outputs SER 800D Supports the following formats 720p 23 98 24 25 29 29 97 30 50 59 94 60 Hz frame freq 1035i 59 94 60 Hz field freq 1080sF 23 98 24 Hz frame freq 1080p 23 98 24 25 29 29 97 30 Hz frame freq 1080i 50 59 94 60 Hz field freq 1 3 Unpacking Make sur...

Страница 32: ...SER 800D E Guide to Installation and Operation 2 ...

Страница 33: ...e 2 1 Overall View of the SER 800D 2 2 SER 800D Installation To install the SER 800D directly on the destination equipment refer to the following diagram Figure 2 2 Connecting the SER 800D SER 800D E Guide to Installation and Operation 3 Loop through BNC connector Input BNC connector Mode slide switch Mounting screws Status LED DC power input connector 50 pin output connector Destination HD SDI vi...

Страница 34: ...gure 2 3 Overall View of the SER 800E 2 4 SER 800E Installation To install the SER 800E directly on the source equipment refer to the following diagram Figure 2 4 Connecting the SER 800E OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE Output BNC connectors Mode slide switch Mounting screws Status LED DC power input connector 50 pin input connector OUT 1 OUT2 STATUS POWER A B HD VIDEO...

Страница 35: ...ignal is output by the D SUB 50 connector You can attach the SER 800D directly to the destina tion equipment by securing the mounting screws to the destina tion equipment female connector The output conforms to SMPTE 260M for 1035i format 296M for 720p format 274M and 295M for 1080sF 1080i and 1080p formats 3 3 SER 800E Operation Parallel HD Video Input Connect a HD parallel video signal to the ma...

Страница 36: ...B 50 pin out SER 800D E Guide to Installation and Operation 6 OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE Mode slide switch Pin Signal Pin Signal Pin Signal 1 CLK 34 CLK 2 Data9 18 Data1 35 Data9 3 Data8 19 Data1 36 Data8 4 Data7 20 Data0 37 Data7 5 Data6 21 Data0 38 Data6 6 Data5 22 GND 39 Data5 7 Data4 23 GND 40 Data4 8 Data3 24 GND 41 Data3 9 Data2 25 GND 42 Data2 10 Data19 26...

Страница 37: ...w ing lists the possible situations Green Indicates that the SER 800D E is powered and has detected a valid HD parallel video input signal Red Indicates an error with the input signal has been detected or simply there is no input cable connected Off The unit is not powered on Check that it is connected to the power supply and the power supply is properly connected to a power source Pin Signal Pin ...

Страница 38: ...SER 800D E Guide to Installation and Operation 8 ...

Страница 39: ... SER CPS Centralized Power Supply Frame Miranda s SER CPS Centralized Power Supply Frame can power up to 10 SER coders A male to male power plug connector is used for the connection between an SER coder and a DC output jack Refer to figure 4 1 DC Power connector pinout for the prop er pinout Figure 4 1 DC Power connector pinout 5 1VDC Ground digital and earth grounds connected together Plug specif...

Страница 40: ...rame Power Fail Indicator Flashes continuously when one of the frame s internal power supplies becomes defective The redundant power supply takes control during this time Rack Mount Holes Four rack mount holes are available for rack mounting 4 2 2 SER CPS Rear Panel Figure 4 3 describes the SER CPS back panel Figure 4 3 SER CPS Rear Panel SER Power Frame POWER FAIL POWER ON Rack mount holes Power ...

Страница 41: ...oth 110 VAC and 220 VAC standards supported Air Vents Keep free from any object in order to maintain proper ventilation 4 2 3 Installation Figure 4 4 describes a typical SER CPS installation Figure 4 4 SER CPS Connections OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 800E MODE OUT 1 OUT2 STATUS POWER A B HD VIDEO SERIALIZER SER 80...

Страница 42: ...wer supply A flashing LED indicates its designated power supply is defective Use the following diagram to locate the defective power supply 3 Once the defective power supply has been located unplug the unit 4 Remove the cable that connects to the defective power supply 5 Remove the four screws that attach the power supply to the frame 6 Replace the defective power supply by a new one and recon nec...

Страница 43: ...ector end installed on the SER 800D E coder is male use the female to female cable adapter provided For cables longer than a few meters twisted pairs should be used for each signal and its return Make sure to connect both ends of the cable in a pin to pin for mat connect pin 1 of source connector to pin 1 of destination connector pin 2 to pin 2 pin 50 to pin 50 For a detail of the connector pinout...

Страница 44: ...SER 800D E Guide to Installation and Operation 14 ...

Страница 45: ...freq SMPTE 260M 1080sF 23 98 24 Hz frame freq SMPTE 274M 1080p 23 98 24 25 29 29 97 30 Hz frame freq SMPTE 274M 1080i 50 59 94 60 Hz field freq SMPTE 274M and 295M Max cable length 2 m 6 Connector D SUB 50 Panasonic or Philips pin out user selectable Outputs SER 800D HD parallel video signal 720p 23 98 24 25 29 29 97 30 50 59 94 60 Hz frame freq SMPTE 296M 1035i 59 94 60 Hz field freq SMPTE 260M 1...

Страница 46: ... ohm Mechanical Dimensions Width 67mm 2 63 Height 20 mm 0 8 Depth 85 mm 3 35 Weight 140g 5oz SER WSU Power Supply regulated Voltage 5 1VDC 0 1VDC Max Current 2 4 A Max Ripple 50mV Connector 2 5mm 5 5mm Plug SER CPS Power Supply Voltage 85 264VAC 47 400Hz Max Power 60W Dimensions Width 483mm 19 Height 1 RU Depth 175mm 6 9 Weight 4kg 8 8lbs NOTE All specifications are subject to change without notif...

Отзывы: