Product Number: QG0005-05 Revision: A0; Date: 6/18/10
9
NV9000 Control System
4) Select ‘Use the following IP address’ and enter an IP
address for the PC:
The IP address must be unique on the house network. (The
subnet mask must be 255.255.255.0.)
5) Click OK and it is done. Close all the Network Connec-
tions windows.
Matching Your House Network
Adding your system controller to your facility’s “house” net-
work is the same as putting your PC on the house net:
1) Go into Windows ‘Network Connection’ on the controller
and find ‘HOUSE NET’.
2) Give it an IP address (and mask) that is unique on your
facility’s network. It should remain a fixed address.
3) Close all network configuration windows.
Installing NV9000 Tools on Your PC
The system controller comes with several useful applications
that you can run if you are logged into the controller.
•
EC9700 (Control GUI).
•
Panel, GUI, and Salvo Editor (a.k.a. PGSE)
•
EC9710 (Status GUI)
•
System Manager
•
Tieline Status GUI
You will probably want to copy these to some or all of your
configuration and GUI PCs.
Follow these steps to distribute the tools:
1) From the system controller, copy
C:\nvision\envy\install\client\SV0269-04.msi
to the target PC.
S
The released tools installer is SV0269-04, version F. However, it
might be in that folder as Setup.exe.
2) Run the installer on the PC. (The installer takes you
through several steps, asks a few questions, and in particu-
lar, asks for the address(es) of you controller(s):
Enter the house net address(es) of the controller(s).
Some of these applications require setup or configuration
in NV9000-SE Utilities. Read the associated manual
(downloadable from the Miranda web site) or call Miranda
tech support.
Misc. Advice
When you use the controller as a computer, you must login
with user ID =
envyadmin
and password =
software
.
If you have only one power cord, you will hear a high-pitched
beep when you turn on your controller. Press the red alarm
mute button at the rear to stop the beeping.
When you turn off your controller, never just disconnect
power. Always use the Windows shutdown command. Other-
wise you risk corrupting system data. Also, use the redundant
power cord. Using a UPS (uninterruptible power source) is
also recommended.
The default pathname of NV9000-SE Utilities configuration
storage is
C:\Documents and Settings\‹
user
›\CtrlSysConfigs
and does not exist until you first launch NV9000-SE Utilities.
The system controller has two built-in power supplies for
redundancy. If power is interrupted, a power supply failure
alarm sounds. This audible alarm does not cease until the
power supply source is once again stable. To turn off the
power supply alarm, press the red power supply alarm mute
button located on the rear of the system controller, as shown
in Figure 2.
Miranda offers several PCI expansion options:
Product
Description
EC9412
A 10/100baseT PCI card that adds one Ethernet port.
EC9414
A 10/100/1000baseT PCI card that adds two Ethernet
ports.
EC9420
An 8-port RS-232/422/485 PCI card with DE9 breakout
box.
USO