Malfunction
Cause
Remedy
No water or very low
flow rate.
Handset sprayplate
blocked.
Remove & clean: Refer to
Maintenance
in the I, O & M
guide for the fittings.
Incoming water supply
stop valves or appliance
isolating valve turned down
or off.
Turn stop/isolating valve fully
to fully on position.
Hose or Handset blocked
Clear blockage or renew
Shower cycles from
hot to cold.
The temperature knob is
positioned at an unsafe
level causing the
appliance thermal trip to
operate and cut the
power to the heater tank.
Turn the temperature knob
sufficiently anti clock-wise to
increase water flow and
reduce temperature.