19
1.19
Connect the 13-Way Multi-Connector
lead from the relay board, in the Mira
Advance ATL, to the socket on the
control PCB located in the cover.
The multi-connector is a one way
fi t into the receiving socket on the
control PCB. Make sure that the
multi-connector is correctly orientated
as illustrated. Make sure that the
connector is pushed home fully.
1.20
Make sure that the 13-Way Multi-
Connector lead is seated between the
tank body and the left hand side of the
case. Then refi t the cover by locating
the top of the cover onto the location
strip on the top of the case.
1.21
Push the bottom of the cover against
the case until it locates correctly.
Install the screw and tighten.
1.22
I f r e q u i r e d , r e f e r t o s e c t i o n :
"Adjustable Temperature Limit"
for setting the maximum temperature
of the shower.
1.23
Route Pump signal cable from
the appliance out of the bathroom
area and connect to the pump,
refer to Whale Shower Drain Pump
manufacturer's recommendations
(Standard Extra and Flex Extra
models only).
Note:
Polarity is not important.
Shower Fittings
1.23
Install the shower fi ttings, refer to
the fittings "Installation and User
Guide".