15
100 mm
Minimum
10 mm Minimum
Rising
Rear Inlet
Supply
Falling
Rear Inlet
Supply
Falling
Supply
Rising
Supply
Front
of Mira
Advance
ATL
?
9
8
1.5
Turn the inlet connector assembly to
suit the supply pipe position. Avoid
trapping the green earth bonding
wire.
1.6
Remove as appropriate, the thinned
sections in the Mira Advance ATL
case, to allow the pipe and cable to
enter the product.
1.7
Install the mains-fed cold water supply
pipe.
C a u t i o n !
D o n o t u s e s e a l i n g
compounds on any pipe fi ttings for
the installation.
The Mira Advance ATL can be
connected to either a compression
fi tting (supplied) or a tap connector
(not supplied).
If upgrading from an existing shower
that uses a tap connector, then
the tap connector adapter can be
used in place of the fi bre washer.
This allows the tap connector to
be used in conjunction with the
compression fitting of the product
(refer to illustration).
For rear inlet supplies, the cold water
pipe must emerge from the surface of
the wall 'square' to prevent straining
the inlet connector clamp bracket.
Refer to illustration for options.
To avoid damage to the Mira Advance
ATL when soldered fi ttings are used,
soldering must not be carried out in
the vicinity of the unit as heat transfer
can damage components.
For connection to a
tap connector use the
tap connector adaptor
(supplied). Do not fi t
the fi bre washer.