Optosense LLC
USER MANUAL
Design department
SMALL-SIZE EXPLOSIVE GAS MEASURING
SENSOR MIPEX-02-X-X-X.1 X (RX)
ESAT.413347.005 UM
Revision 3.0
January 19th, 2017
Page 7 of 46
THE SOLE PROPERTY OF OPTOSENSE LLC. ANY REPRODUCTION WITHOUT THE WRITTEN PERMISSION OF OPTOSENSE LLC IS PROHIBITED.
3. TECHNICAL SPECIFICATIONS
Table 2. General specifications (for available options see Appendix A)
Gas sampling method
Diffusion
Operating principle
Non-Dispersive Infra-Red (NDIR)
Target gas
1
CH
4
CH
4
/CH
4
+С
2
Н
6
C
3
H
8
CO
2
Operating,
storage and
transportation
conditions:
Relative humidity, %
up to 98
Atmospheric pressure, kPa
80…120
Temperature
2
, °C
-55...+60
Temperature range
, °C
-
10…+40
-
40…+60
-
20…+50
Overall dimensions, mm
⌀
20.2×16.6 (without pins; housing types “1” and “3”)
3
⌀
22×16.6 (without pins; housing type “2”)
Pins length, mm
4.6
5.75
Warm-up time, sec
≤ 120
Weight, g
16.6 (
housing type “1”)
15.5 (
housing type “2”)
5.5 (
housing type “3”)
Housing material
Stainless steel (
housing types “1” and “2”)
Plastic
Lexan™ (housing type “3”)
Life time expectancy
4
(not less than), years
10
Shelf life time (not less than), years
8
IP rating
20 (without dust filter)
54 (if a dust filter provided by Optosense LLC is
applied)
1
See Appendix A for details.
2
Term “operating temperature” refers to ambient temperature, at which sensor operates and its
intrinsic safety is ensured, but sensor readings variability stated in Table 3 is provided only in specified
temperature range (see Table 5 and Table 6).
3
For information on housing types, see Appendix A.
4
To provide metrological properties during sensor lifetime, zeroing and span calibration should be
performed periodically, at least once in 30 months (see Appendix D.1).